arXiv:1303.6741 · Physical Review Letters

Optical Spectrum Analyzer with Quantum-Limited Noise Floor

Michael Bishof, Xiaogang Zhang, Michael J. Martin, Jun Ye

Published Aug 30, 2013• 79 citations
arXivHTMLPDF

Abstract

Interactions between atoms and lasers provide the potential for unprecedented control of quantum states. Fulfilling this potential requires detailed knowledge of frequency noise in optical oscillators with state-of-the-art stability. We demonstrate a technique that precisely measures the noise spectrum of an ultrastable laser using optical lattice-trapped 87Sr atoms as a quantum projection noise-limited reference. We determine the laser noise spectrum from near dc to 100 Hz via the measured fluctuations in atomic excitation, guided by a simple and robust theory model. The noise spectrum yields a 26(4) mHz linewidth at a central frequency of 429 THz, corresponding to an optical quality factor of 1.6×10(16). This approach improves upon optical heterodyne beats between two similar laser systems by providing information unique to a single laser and complements the traditionally used Allan deviation which evaluates laser performance at relatively long time scales. We use this technique to verify the reduction of resonant noise in our ultrastable laser via feedback from an optical heterodyne beat. Finally, we show that knowledge of our laser's spectrum allows us to accurately predict the laser-limited stability for optical atomic clocks.

DOI
10.1103/physrevlett.111.093604

Related papers

Quantum Metrology and Many-Body Physics: Pushing the Frontier of the Optical Lattice Clock

Michael J. Martin

Neutral atom optical standards require the highest levels of laser precision to operate near the limit set by quantum fluctuations. We develop state-of-the-art ultra-stable laser systems to achieve a factor of 10 enhancement in clock measurement precision and additionally demonstrate optical linewidths below 50 mHz. The most stable of these lasers reaches its thermal noise floor of 1 × 10-16 fractional frequency instability, allowing the attainment of near quantum-noise-limited clock operation with single-clock instabilities of 3×10-16 at 1 s. We utilize this high level of spectral resolution to operate a 87Sr optical lattice clock in a regime in which quantum collisions play a dominant role in the dynamics, enabling the study of quantum many-body physics. With a fractional level of precision of near 1 × 10-16 at 1 s, we clearly resolve the signatures of many-body interactions. We find that the complicated interplay between the p wave-dominated elastic and inelastic interaction processes between lattice-trapped atoms leads to severe lineshape distortion, shifts, and loss of Ramsey fringe contrast. We additionally explore the theoretical prediction that these many-body interactions will modify the quantum fluctuations of the system and we find that in certain parameter regimes the quantum noise distribution exhibits a quadrature dependence. We further present technological advancements that will permit ultra-stable lasers to operate with reduced thermal noise, leading to a potential gain of an additional factor of 10 in stability. This indicates that laser fractional frequency instabilities of 1 × 10-17 are within experimental reach, as is a fully-quantum-limited regime of optical clock operation.

•Jan 1, 2013•18 citations

Frequency comparison of optical lattice clocks

Masao Takamoto, T. Takano, Hidetoshi Katori

We demonstrate the frequency comparison of two optical lattice clocks at the relative stabilities close to the quantum projection noise (QPN) limit of optical lattice clocks. This stable frequency comparison is accomplished by synchronous interrogations of two clocks by a common probe laser, which allows us to cancel out the probe laser's frequency noise. We perform the frequency comparison of a one-dimensional (1D) optical lattice clock with spin-polarized fermions 87Sr and a three-dimensional (3D) optical lattice clock with unity-occupation bosons 88Sr and achieve the Allan standard deviation of σγ(τ)=4×10-16 τ-1/2, which corresponds to the QPN limited stability for N=1,000 atoms and the spectrum linewidth γ=8 Hz. The relative stability reaches 1×10-17 with an averaging time of 1,600 s. Finally, we discuss the prospects to realize 10-18 fractional inaccuracies and the possible application of frequency comparison with synchronous interrogations to remote clocks' comparison for relativistic geodesy.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 8, 2011•0 citations

Quantum Projection Noise in an Atomic Fountain: A High Stability Cesium Frequency Standard

Giorgio Santarelli, Philippe Laurent, P. Lemonde +5 more

We describe the operation of a laser cooled cesium fountain clock in the quantum limited regime. An ultrastable cryogenic sapphire oscillator is used to measure the short-term frequency stability of the fountain as a function of the number of detected atoms ${N}_{\mathrm{at}}$. For ${N}_{\mathrm{at}}$ varying from $4\ifmmode\times\else\texttimes\fi{}{10}^{4}$ to $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ the Allan standard deviation of the frequency fluctuations is in excellent agreement with the ${N}_{\mathrm{at}}^{\ensuremath{-}1/2}$ law of atomic projection noise. With $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ atoms, the relative frequency stability is $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$, where \ensuremath{\tau} is the integration time in seconds. This is the best short-term stability ever reported for primary frequency standards, a factor of 5 improvement over previous results.

Physical Review Letters•Jun 7, 1999•568 citations

Understanding atomic interactions in an optical lattice clock and using them to study many-body physics

Michael Bishof

Strontium optical lattice clocks at JILA recently demonstrated record-high accuracy and stability. These advances were enabled by an ultrastable laser with fractional frequency stability of 1x10-16 at 1 second. This laser allows us to study systematic shifts of the 1S0 to 3P0 clock transition with unprecedented precision. Density-dependent frequency shifts represent an unavoidable perturbation for clocks based on many atoms. Our studies of atomic interactions in an optical lattice clock system uncover the nature of these interactions and reveal important many-body atomic correlation effects in this open quantum system. By extending our measurements to all ten nuclear-spin sublevels of the clock states, we observe the first direct evidence of SU(N) symmetric interactions in alkaline earth(-like) atoms. Using the techniques we developed in these studies, we also demonstrate a novel technique for measuring the frequency noise spectrum of an ultrastable laser. We discuss designs for the future direction of our experiment which will place 87Sr atoms within a high finesse cavity that is resonant on the 1S0 to 3P1 transition. We will use this system to study collective effects in cavity quantum electrodynamics. Most notably, strong atom-cavity coupling can enhance the spectroscopic sensitivity of our clock by creating spin-squeezed states via quantum non-demolition measurements. As a precursor to future work studying cavity-mediated collective behavior, we use the unique atomic structure of 88Sr to investigate free-space retarded dipolar coupling in an optically thick sample of atoms.

•Jan 1, 2014•0 citations

Comb-assisted ultrastable laser system for quantum technologies

Michele Giunta, Martin Wolferstetter, Nikolai Lilienfein +5 more

Quantum technologies are nowadays emerging as enabling tools for practical applications, such as quantum sensing, quantum computing and quantum metrology. Lasers play a central role in many of these technological platforms, e.g. for atomic clocks, ion-based or neutral atom-based quantum computers or atom interferometers. Here we present a complete laser system to cool, trap and control strontium atoms in an optical lattice or in tweezer arrays. A sub-Hz linewidth master laser, locked to a high-finesse optical cavity provides the frequency reference for an ultra-low noise comb. The rack-mounted laser system consists of all cooling, repumping, and clock lasers stabilized to the optical frequency comb. Each of the involved laser frequencies can therefore be tuned and mapped in the frequency domain with a high degree of stability. The system is controlled via a software interface, allowing to operate the cold-atom-based physics package autonomously. The system is tailored for the operation of 88Sr or 87Sr optical lattice clocks, or for quantum computing applications, but other sub-Hz lasers could be obtained by phase locking additional clock laser frequencies to the ultra-stable comb, enabling convenient and accurate optical frequency ratio measurements. The laser system architecture and the relevant characterization measurements will be presented, proposing some user-cases such as quantum computing and atom interferometry on strontium atoms. This represents a technological leap for quantum optics, allowing to explore further applications of quantum sensors outside a traditional lab.

Optical and Quantum Sensing and Precision Metrology•Mar 4, 2021•1 citation

Comparison of Two Independent Sr Optical Clocks with 1 × 10 − 17 Stability at 10 3 s

Travis Nicholson, Michael J. Martin, Jason Williams +5 more

Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been limited by frequency noise of optical local oscillators. By synchronously probing two $^{87}\mathrm{Sr}$ lattice systems using a laser with a thermal noise floor of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, we remove classically correlated laser noise from the intercomparison, but this does not demonstrate independent clock performance. With an improved optical oscillator that has a $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$ thermal noise floor, we demonstrate an order of magnitude improvement over the best reported stability of any independent clock, achieving a fractional instability of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ in 1000 s of averaging time for synchronous or asynchronous comparisons. This result is within a factor of 2 of the combined quantum projection noise limit for a 160 ms probe time with $\ensuremath{\sim}{10}^{3}$ atoms in each clock. We further demonstrate that even at this high precision, the overall systematic uncertainty of our clock is not limited by atomic interactions. For the second Sr clock, which has a cavity-enhanced lattice, the atomic-density-dependent frequency shift is evaluated to be $\ensuremath{-}3.11\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ with an uncertainty of $8.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$.

arXiv:1210.0064•Physical Review Letters•Dec 5, 2012•204 citations
Interactions between atoms and lasers provide the potential for unprecedented control of quantum states. Fulfilling this potential requires detailed knowledge of frequency noise in optical oscillators with state-of-the-art stability. We demonstrate a technique that precisely measures the noise spectrum of an ultrastable laser using optical lattice-trapped 87Sr atoms as a quantum projection noise-limited reference. We determine the laser noise spectrum from near dc to 100 Hz via the measured fluctuations in atomic excitation, guided by a simple and robust theory model. The noise spectrum yields a 26(4) mHz linewidth at a central frequency of 429 THz, corresponding to an optical quality factor of 1.6×10(16). This approach improves upon optical heterodyne beats between two similar laser systems by providing information unique to a single laser and complements the traditionally used Allan deviation which evaluates laser performance at relatively long time scales. We use this technique to verify the reduction of resonant noise in our ultrastable laser via feedback from an optical heterodyne beat. Finally, we show that knowledge of our laser's spectrum allows us to accurately predict the laser-limited stability for optical atomic clocks.
Neutral atom optical standards require the highest levels of laser precision to operate near the limit set by quantum fluctuations. We develop state-of-the-art ultra-stable laser systems to achieve a factor of 10 enhancement in clock measurement precision and additionally demonstrate optical linewidths below 50 mHz. The most stable of these lasers reaches its thermal noise floor of 1 × 10-16 fractional frequency instability, allowing the attainment of near quantum-noise-limited clock operation with single-clock instabilities of 3×10-16 at 1 s. We utilize this high level of spectral resolution to operate a 87Sr optical lattice clock in a regime in which quantum collisions play a dominant role in the dynamics, enabling the study of quantum many-body physics. With a fractional level of precision of near 1 × 10-16 at 1 s, we clearly resolve the signatures of many-body interactions. We find that the complicated interplay between the p wave-dominated elastic and inelastic interaction processes between lattice-trapped atoms leads to severe lineshape distortion, shifts, and loss of Ramsey fringe contrast. We additionally explore the theoretical prediction that these many-body interactions will modify the quantum fluctuations of the system and we find that in certain parameter regimes the quantum noise distribution exhibits a quadrature dependence. We further present technological advancements that will permit ultra-stable lasers to operate with reduced thermal noise, leading to a potential gain of an additional factor of 10 in stability. This indicates that laser fractional frequency instabilities of 1 × 10-17 are within experimental reach, as is a fully-quantum-limited regime of optical clock operation.
We demonstrate the frequency comparison of two optical lattice clocks at the relative stabilities close to the quantum projection noise (QPN) limit of optical lattice clocks. This stable frequency comparison is accomplished by synchronous interrogations of two clocks by a common probe laser, which allows us to cancel out the probe laser's frequency noise. We perform the frequency comparison of a one-dimensional (1D) optical lattice clock with spin-polarized fermions 87Sr and a three-dimensional (3D) optical lattice clock with unity-occupation bosons 88Sr and achieve the Allan standard deviation of σγ(τ)=4×10-16 τ-1/2, which corresponds to the QPN limited stability for N=1,000 atoms and the spectrum linewidth γ=8 Hz. The relative stability reaches 1×10-17 with an averaging time of 1,600 s. Finally, we discuss the prospects to realize 10-18 fractional inaccuracies and the possible application of frequency comparison with synchronous interrogations to remote clocks' comparison for relativistic geodesy.
We describe the operation of a laser cooled cesium fountain clock in the quantum limited regime. An ultrastable cryogenic sapphire oscillator is used to measure the short-term frequency stability of the fountain as a function of the number of detected atoms Nat{N}_{\mathrm{at}}Nat​. For Nat{N}_{\mathrm{at}}Nat​ varying from $4\ifmmode\times\else\texttimes\fi{}{10}^{4}$ to $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ the Allan standard deviation of the frequency fluctuations is in excellent agreement with the ${N}_{\mathrm{at}}^{\ensuremath{-}1/2}$ law of atomic projection noise. With $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ atoms, the relative frequency stability is $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$, where \ensuremath{\tau} is the integration time in seconds. This is the best short-term stability ever reported for primary frequency standards, a factor of 5 improvement over previous results.
Strontium optical lattice clocks at JILA recently demonstrated record-high accuracy and stability. These advances were enabled by an ultrastable laser with fractional frequency stability of 1x10-16 at 1 second. This laser allows us to study systematic shifts of the 1S0 to 3P0 clock transition with unprecedented precision. Density-dependent frequency shifts represent an unavoidable perturbation for clocks based on many atoms. Our studies of atomic interactions in an optical lattice clock system uncover the nature of these interactions and reveal important many-body atomic correlation effects in this open quantum system. By extending our measurements to all ten nuclear-spin sublevels of the clock states, we observe the first direct evidence of SU(N) symmetric interactions in alkaline earth(-like) atoms. Using the techniques we developed in these studies, we also demonstrate a novel technique for measuring the frequency noise spectrum of an ultrastable laser. We discuss designs for the future direction of our experiment which will place 87Sr atoms within a high finesse cavity that is resonant on the 1S0 to 3P1 transition. We will use this system to study collective effects in cavity quantum electrodynamics. Most notably, strong atom-cavity coupling can enhance the spectroscopic sensitivity of our clock by creating spin-squeezed states via quantum non-demolition measurements. As a precursor to future work studying cavity-mediated collective behavior, we use the unique atomic structure of 88Sr to investigate free-space retarded dipolar coupling in an optically thick sample of atoms.
Quantum technologies are nowadays emerging as enabling tools for practical applications, such as quantum sensing, quantum computing and quantum metrology. Lasers play a central role in many of these technological platforms, e.g. for atomic clocks, ion-based or neutral atom-based quantum computers or atom interferometers. Here we present a complete laser system to cool, trap and control strontium atoms in an optical lattice or in tweezer arrays. A sub-Hz linewidth master laser, locked to a high-finesse optical cavity provides the frequency reference for an ultra-low noise comb. The rack-mounted laser system consists of all cooling, repumping, and clock lasers stabilized to the optical frequency comb. Each of the involved laser frequencies can therefore be tuned and mapped in the frequency domain with a high degree of stability. The system is controlled via a software interface, allowing to operate the cold-atom-based physics package autonomously. The system is tailored for the operation of 88Sr or 87Sr optical lattice clocks, or for quantum computing applications, but other sub-Hz lasers could be obtained by phase locking additional clock laser frequencies to the ultra-stable comb, enabling convenient and accurate optical frequency ratio measurements. The laser system architecture and the relevant characterization measurements will be presented, proposing some user-cases such as quantum computing and atom interferometry on strontium atoms. This represents a technological leap for quantum optics, allowing to explore further applications of quantum sensors outside a traditional lab.
Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been limited by frequency noise of optical local oscillators. By synchronously probing two 87Sr^{87}\mathrm{Sr}87Sr lattice systems using a laser with a thermal noise floor of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, we remove classically correlated laser noise from the intercomparison, but this does not demonstrate independent clock performance. With an improved optical oscillator that has a $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$ thermal noise floor, we demonstrate an order of magnitude improvement over the best reported stability of any independent clock, achieving a fractional instability of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ in 1000 s of averaging time for synchronous or asynchronous comparisons. This result is within a factor of 2 of the combined quantum projection noise limit for a 160 ms probe time with $\ensuremath{\sim}{10}^{3}$ atoms in each clock. We further demonstrate that even at this high precision, the overall systematic uncertainty of our clock is not limited by atomic interactions. For the second Sr clock, which has a cavity-enhanced lattice, the atomic-density-dependent frequency shift is evaluated to be $\ensuremath{-}3.11\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ with an uncertainty of $8.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$.