arXiv:1302.4822 · Review of Scientific Instruments

Modular cryostat for ion trapping with surface-electrode ion traps

Grahame Vittorini, Kenneth Wright, Kenneth R. Brown, Alexa W. Harter, S. Charles Doret

Published Apr 1, 2013• 24 citations
arXivHTMLPDF

Abstract

We present a simple cryostat purpose built for use with surface-electrode ion traps, designed around an affordable, large cooling power commercial pulse tube refrigerator. A modular vacuum enclosure with a single vacuum space facilitates interior access and enables rapid turnaround and flexibility for future modifications. Long rectangular windows provide nearly 360° of optical access in the plane of the ion trap, while a circular bottom window near the trap enables NA 0.4 light collection without the need for in-vacuum optics. We evaluate the system's mechanical and thermal characteristics and we quantify ion trapping performance by trapping (40)Ca(+), finding small stray electric fields, long ion lifetimes, and low ion heating rates.

DOI
10.1063/1.4802948

Related papers

Stability of ion chains in a cryogenic surface-electrode ion trap

Grahame Vittorini

Cold, trapped atomic ions have enabled the investigation of fundamental physics and generated a rich field of applications. Foremost among these is quantum computation which has recently driven the development of the sophisticated, scalable surface-electrode trap. Despite the many advantages of surface-electrode traps, the typically smaller ion-electrode distance, d, in these traps results in an increased ion heating rate that is proportional to d^(-4) and a decreased trap well-depth that is proportional to d^(-2). These shortcomings can be simultaneously addressed by installing the trap into a cryogenic environment. With this in mind, a closed-cycle, cryogenic ion trapping apparatus that maintains excellent vacuum, is highly modular, has increased optical access, and uses a simple vibration isolation system has been developed. \n \nSingle ions are trapped and used to characterize system properties such as the motion of the vibration isolation stage. In order to compare this system to a similar room temperature apparatus, the ion trapping lifetime and heating rate are determined. A single ion also serves as a sensitive electric field probe that is used to measure and compensate stray electric fields across the trap. \n \nDue to the long dark ion lifetimes in this system, it is well-suited to probing the stability of small, linear ion crystals. Linear ion crystals of arbitrary length are built in an automated fashion using transport waveforms and the scaling of dark lifetime with ion number for N <= 6 is investigated. These data are then used to consider the relevance of various loss channels.

Bulletin of the American Physical Society•Sep 10, 2013•1 citation

Cryogenic ion trapping systems with surface-electrode traps

Paul Antohi, David Schuster, Gleb M. Akselrod +5 more

We present two simple cryogenic rf ion trap systems in which cryogenic temperatures and ultra high vacuum pressures can be reached in as little as 12 h. The ion traps are operated either in a liquid helium bath cryostat or in a low vibration closed cycle cryostat. The fast turn around time and availability of buffer gas cooling made the systems ideal for testing surface-electrode ion traps. The vibration amplitude of the closed cycled cryostat was found to be below 106 nm. We evaluated the systems by loading surface-electrode ion traps with (88)Sr(+) ions using laser ablation, which is compatible with the cryogenic environment. Using Doppler cooling we observed small ion crystals in which optically resolved ions have a trapped lifetime over 2500 min.

arXiv:0807.4763•Review of Scientific Instruments•Jan 1, 2009•47 citations

High-Stability Cryogenic System for Quantum Computing With Compact Packaged Ion Traps

Robert Spivey, I. V. Inlek, Zhubing Jia +9 more

Cryogenic environments benefit ion trapping experiments by offering lower motional heating rates, collision energies, and an ultrahigh vacuum (UHV) environment for maintaining long ion chains for extended periods of time. Mechanical vibrations caused by compressors in closed-cycle cryostats can introduce relative motion between the ion and the wavefronts of lasers used to manipulate the ions. Here, we present a novel ion trapping system where a commercial low-vibration closed-cycle cryostat is used in a custom monolithic enclosure. We measure mechanical vibrations of the sample stage using an optical interferometer, and observe a root-mean-square relative displacement of 2.4 nm and a peak-to-peak displacement of 17 nm between free-space beams and the trapping location. We packaged a surface ion trap in a cryopackage assembly that enables easy handling while creating a UHV environment for the ions. The trap cryopackage contains activated carbon getter material for enhanced sorption pumping near the trapping location, and source material for ablation loading. Using$^{171}$Yb$^{+}$as our ion, we estimate the operating pressure of the trap as a function of package temperature using phase transitions of zig-zag ion chains as a probe. We measured the radial mode heating rate of a single ion to be 13 quanta/s on average. The Ramsey coherence measurements yield 330-ms coherence time for counter-propagating Raman carrier transitions using a 355-nm mode-locked pulse laser, demonstrating the high optical stability.

arXiv:2108.05290•IEEE Transactions on Quantum Engineering•Nov 8, 2021•33 citations

Cryogenic setup for trapped ion quantum computing

M. F. Brandl, M. W. van Mourik, L. Postler +15 more

We report on the design of a cryogenic setup for trapped ion quantum computing containing a segmented surface electrode trap. The heat shield of our cryostat is designed to attenuate alternating magnetic field noise, resulting in 120 dB reduction of 50 Hz noise along the magnetic field axis. We combine this efficient magnetic shielding with high optical access required for single ion addressing as well as for efficient state detection by placing two lenses each with numerical aperture 0.23 inside the inner heat shield. The cryostat design incorporates vibration isolation to avoid decoherence of optical qubits due to the motion of the cryostat. We measure vibrations of the cryostat of less than ±20 nm over 2 s. In addition to the cryogenic apparatus, we describe the setup required for an operation with 40Ca+ and 88Sr+ ions. The instability of the laser manipulating the optical qubits in 40Ca+ is characterized by yielding a minimum of its Allan deviation of 2.4 ⋅ 10−15 at 0.33 s. To evaluate the performance of the apparatus, we trapped 40Ca+ ions, obtaining a heating rate of 2.14(16) phonons/s and a Gaussian decay of the Ramsey contrast with a 1/e-time of 18.2(8) ms.

arXiv:1607.04980•Review of Scientific Instruments•Nov 1, 2016•77 citations

Cryogenic setup for trapped ion quantum computing.

Brandl, MF, van Mourik, MW, Postler, L +15 more

We report on the design of a cryogenic setup for trapped ion quantum computing containing a segmented surface electrode trap. The heat shield of our cryostat is designed to attenuate alternating magnetic field noise, resulting in 120 dB reduction of 50 Hz noise along the magnetic field axis. We combine this efficient magnetic shielding with high optical access required for single ion addressing as well as for efficient state detection by placing two lenses each with numerical aperture 0.23 inside the inner heat shield. The cryostat design incorporates vibration isolation to avoid decoherence of optical qubits due to the motion of the cryostat. We measure vibrations of the cryostat of less than ±20 nm over 2 s. In addition to the cryogenic apparatus, we describe the setup required for an operation with 40Ca+ and 88Sr+ ions. The instability of the laser manipulating the optical qubits in 40Ca+ is characterized by yielding a minimum of its Allan deviation of 2.4 ⋅ 10-15 at 0.33 s. To evaluate the performance of the apparatus, we trapped 40Ca+ ions, obtaining a heating rate of 2.14(16) phonons/s and a Gaussian decay of the Ramsey contrast with a 1/e-time of 18.2(8) ms.

•Nov 1, 2016•26 citations

In-vacuum active electronics for microfabricated ion traps

Nicholas D. Guise, Spencer D. Fallek, Harley Hayden +10 more

The advent of microfabricated ion traps for the quantum information community has allowed research groups to build traps that incorporate an unprecedented number of trapping zones. However, as device complexity has grown, the number of digital-to-analog converter (DAC) channels needed to control these devices has grown as well, with some of the largest trap assemblies now requiring nearly one hundred DAC channels. Providing electrical connections for these channels into a vacuum chamber can be bulky and difficult to scale beyond the current numbers of trap electrodes. This paper reports on the development and testing of an in-vacuum DAC system that uses only 9 vacuum feedthrough connections to control a 78-electrode microfabricated ion trap. The system is characterized by trapping single and multiple (40)Ca(+) ions. The measured axial mode stability, ion heating rates, and transport fidelities for a trapped ion are comparable to systems with external (air-side) commercial DACs.

arXiv:1403.3662•Review of Scientific Instruments•Jun 1, 2014•25 citations
We present a simple cryostat purpose built for use with surface-electrode ion traps, designed around an affordable, large cooling power commercial pulse tube refrigerator. A modular vacuum enclosure with a single vacuum space facilitates interior access and enables rapid turnaround and flexibility for future modifications. Long rectangular windows provide nearly 360° of optical access in the plane of the ion trap, while a circular bottom window near the trap enables NA 0.4 light collection without the need for in-vacuum optics. We evaluate the system's mechanical and thermal characteristics and we quantify ion trapping performance by trapping (40)Ca(+), finding small stray electric fields, long ion lifetimes, and low ion heating rates.
Cold, trapped atomic ions have enabled the investigation of fundamental physics and generated a rich field of applications. Foremost among these is quantum computation which has recently driven the development of the sophisticated, scalable surface-electrode trap. Despite the many advantages of surface-electrode traps, the typically smaller ion-electrode distance, d, in these traps results in an increased ion heating rate that is proportional to d^(-4) and a decreased trap well-depth that is proportional to d^(-2). These shortcomings can be simultaneously addressed by installing the trap into a cryogenic environment. With this in mind, a closed-cycle, cryogenic ion trapping apparatus that maintains excellent vacuum, is highly modular, has increased optical access, and uses a simple vibration isolation system has been developed. \n \nSingle ions are trapped and used to characterize system properties such as the motion of the vibration isolation stage. In order to compare this system to a similar room temperature apparatus, the ion trapping lifetime and heating rate are determined. A single ion also serves as a sensitive electric field probe that is used to measure and compensate stray electric fields across the trap. \n \nDue to the long dark ion lifetimes in this system, it is well-suited to probing the stability of small, linear ion crystals. Linear ion crystals of arbitrary length are built in an automated fashion using transport waveforms and the scaling of dark lifetime with ion number for N <= 6 is investigated. These data are then used to consider the relevance of various loss channels.
We present two simple cryogenic rf ion trap systems in which cryogenic temperatures and ultra high vacuum pressures can be reached in as little as 12 h. The ion traps are operated either in a liquid helium bath cryostat or in a low vibration closed cycle cryostat. The fast turn around time and availability of buffer gas cooling made the systems ideal for testing surface-electrode ion traps. The vibration amplitude of the closed cycled cryostat was found to be below 106 nm. We evaluated the systems by loading surface-electrode ion traps with (88)Sr(+) ions using laser ablation, which is compatible with the cryogenic environment. Using Doppler cooling we observed small ion crystals in which optically resolved ions have a trapped lifetime over 2500 min.
Cryogenic environments benefit ion trapping experiments by offering lower motional heating rates, collision energies, and an ultrahigh vacuum (UHV) environment for maintaining long ion chains for extended periods of time. Mechanical vibrations caused by compressors in closed-cycle cryostats can introduce relative motion between the ion and the wavefronts of lasers used to manipulate the ions. Here, we present a novel ion trapping system where a commercial low-vibration closed-cycle cryostat is used in a custom monolithic enclosure. We measure mechanical vibrations of the sample stage using an optical interferometer, and observe a root-mean-square relative displacement of 2.4 nm and a peak-to-peak displacement of 17 nm between free-space beams and the trapping location. We packaged a surface ion trap in a cryopackage assembly that enables easy handling while creating a UHV environment for the ions. The trap cryopackage contains activated carbon getter material for enhanced sorption pumping near the trapping location, and source material for ablation loading. Using171^{171}171Yb+^{+}+as our ion, we estimate the operating pressure of the trap as a function of package temperature using phase transitions of zig-zag ion chains as a probe. We measured the radial mode heating rate of a single ion to be 13 quanta/s on average. The Ramsey coherence measurements yield 330-ms coherence time for counter-propagating Raman carrier transitions using a 355-nm mode-locked pulse laser, demonstrating the high optical stability.
We report on the design of a cryogenic setup for trapped ion quantum computing containing a segmented surface electrode trap. The heat shield of our cryostat is designed to attenuate alternating magnetic field noise, resulting in 120 dB reduction of 50 Hz noise along the magnetic field axis. We combine this efficient magnetic shielding with high optical access required for single ion addressing as well as for efficient state detection by placing two lenses each with numerical aperture 0.23 inside the inner heat shield. The cryostat design incorporates vibration isolation to avoid decoherence of optical qubits due to the motion of the cryostat. We measure vibrations of the cryostat of less than ±20 nm over 2 s. In addition to the cryogenic apparatus, we describe the setup required for an operation with 40Ca+ and 88Sr+ ions. The instability of the laser manipulating the optical qubits in 40Ca+ is characterized by yielding a minimum of its Allan deviation of 2.4 ⋅ 10−15 at 0.33 s. To evaluate the performance of the apparatus, we trapped 40Ca+ ions, obtaining a heating rate of 2.14(16) phonons/s and a Gaussian decay of the Ramsey contrast with a 1/e-time of 18.2(8) ms.
We report on the design of a cryogenic setup for trapped ion quantum computing containing a segmented surface electrode trap. The heat shield of our cryostat is designed to attenuate alternating magnetic field noise, resulting in 120 dB reduction of 50 Hz noise along the magnetic field axis. We combine this efficient magnetic shielding with high optical access required for single ion addressing as well as for efficient state detection by placing two lenses each with numerical aperture 0.23 inside the inner heat shield. The cryostat design incorporates vibration isolation to avoid decoherence of optical qubits due to the motion of the cryostat. We measure vibrations of the cryostat of less than ±20 nm over 2 s. In addition to the cryogenic apparatus, we describe the setup required for an operation with 40Ca+ and 88Sr+ ions. The instability of the laser manipulating the optical qubits in 40Ca+ is characterized by yielding a minimum of its Allan deviation of 2.4 ⋅ 10-15 at 0.33 s. To evaluate the performance of the apparatus, we trapped 40Ca+ ions, obtaining a heating rate of 2.14(16) phonons/s and a Gaussian decay of the Ramsey contrast with a 1/e-time of 18.2(8) ms.
The advent of microfabricated ion traps for the quantum information community has allowed research groups to build traps that incorporate an unprecedented number of trapping zones. However, as device complexity has grown, the number of digital-to-analog converter (DAC) channels needed to control these devices has grown as well, with some of the largest trap assemblies now requiring nearly one hundred DAC channels. Providing electrical connections for these channels into a vacuum chamber can be bulky and difficult to scale beyond the current numbers of trap electrodes. This paper reports on the development and testing of an in-vacuum DAC system that uses only 9 vacuum feedthrough connections to control a 78-electrode microfabricated ion trap. The system is characterized by trapping single and multiple (40)Ca(+) ions. The measured axial mode stability, ion heating rates, and transport fidelities for a trapped ion are comparable to systems with external (air-side) commercial DACs.