Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1205.1637 · Physical Review A

Disclosing the spatiotemporal structure of parametric down-conversion entanglement through frequency up-conversion

E. Brambilla, Ottavia Jedrkiewicz, Luigi A. Lugiato, A. Gatti

Published Jun 25, 2012• 25 citations
arXivHTMLPDF

Abstract

In this work we propose and analyze a scheme where the full spatiotemporal correlation of twin photons or beams generated by parametric down-conversion is detected by using its inverse process, i.e., sum frequency generation. Our main result is that, by imposing independently a temporal delay $\ensuremath{\Delta}t$ and a transverse spatial shift $\ensuremath{\Delta}x$ between two twin components of PDC light, the up-converted light intensity provides information on the correlation of the PDC light in the full spatiotemporal domain and should enable the reconstruction of the peculiar X-shaped structure of the correlation predicted previously [A. Gatti et al. Phys. Rev. Lett. 102, 223601 (2009); L. Caspani et al. Phys. Rev. A 81, 033808 (2010); E. Brambilla et al. Phys. Rev. A 82, 013835 (2010)]. Through both a semianalytical and a numerical modeling of the proposed optical system, we analyze the feasibility of the experiment and identify the best conditions to implement it. In particular, the tolerance of the phase-sensitive measurement against the presence of dispersive elements, imperfect imaging conditions, and possible misalignments of the two crystals is evaluated.

DOI
10.1103/physreva.85.063834

Related papers

Experimental investigation of the X-shaped spatio-temporal correlation of twin photons via sum frequency generation

Ottavia Jedrkiewicz, E. Brambilla, P. Di Trapani +2 more

In this paper we report about the experimental investigation of the non factorable spatio-temporal correlation of twin beams generated in parametric down conversion (PDC) at the crystal output. We present the correlation features to be reconstructed by means of the inverse process of PDC, that is sum frequency generation, in a scheme based on achromatic imaging. In particular we show the ultra-narrow temporal localization (6fs) observed thanks to the huge spectral bandwidth detected in the near field of the crystal. We illustrate the deteriorating effects of imperfect imaging conditions or spatial modes selection on the temporal correlation, giving evidence of the interdependence of spatial and temporal degrees of freedom in PDC as claimed by the theory. Throughout the paper we shall discuss about the characteristics of the experimental set-up being used for the investigation of the twin beam correlation in both the temporal and spatial domain, highlighting the important features for the success of the experiment and the demonstration of the X-shaped structure of the space-time correlation, already emerging from preliminary results.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 15, 2012•0 citations

Exploring the spatio-temporal correlation of twin photons via frequency up-conversion

E. Brambilla, A. Gatti, Ottavia Jedrkiewicz +3 more

The entangled photon pairs (biphotons) produced from parametric down-conversion (PDC) in a χ(2)crystal are the key element for several quantum information and communication schemes. Recent theoretical investigations [1–2] have revealed the peculiar structure of the biphotonic correlation characterizing the entanglement of twin beams in the space-time domain. The biphotonic correlation in type I PDC is characterized in the near field by a X-shaped geometry, which turns out to be non-factorable in space and time, offering thus the relevant possibility of manipulating the temporal bandwidth of biphoton entanglement by acting on their spatial degrees of freedom. The name “X-entanglement” was coined to describe this geometry [1]. An other key feature which emerged is the extreme spatial and temporal localization of the biphotonic correlation, on the micrometer and femtosecond range, respectively.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•May 1, 2011•0 citations

Experimental Observation of a Skewed X-type Spatiotemporal Correlation of Ultrabroadband Twin Beams

Ottavia Jedrkiewicz, A. Gatti, E. Brambilla +1 more

This work presents the experimental observation of the nonfactorable near-field spatiotemporal correlation of ultrabroadband twin beams generated by parametric down-conversion, in an interferometric-type experiment using sum frequency generation, where both the temporal and the spatial degrees of freedom of parametric down-conversion light are controlled with high resolution. The revealed correlation is skewed in space-time in accordance with the X structure predicted by the theory.

arXiv:1207.6934•Physical Review Letters•Dec 10, 2012•23 citations

Spatiotemporal structure of biphoton entanglement in type-II parametric down-conversion

E. Brambilla, Lucia Caspani, Luigi A. Lugiato +1 more

We investigate the spatiotemporal structure of the biphoton correlation in type-II parametric down-conversion (PDC). As in type-I PDC [Phys. Rev. Lett. 102, 223601 (2009)], we find that the correlation is nonfactorizable in space and time. Differently from type I, the type-II correlation in the spontaneous regime displays an asymmetric V-shaped structure in any cross section including time and one transverse dimension. This asymmetry along the temporal coordinate originates from the signal-idler group velocity mismatch and tends to disappear as the parametric gain is raised. We observe a progressive transition toward a symmetric X-shaped geometry similar to that found in type I when stimulated PDC becomes dominant. We also give quantitative evaluations of the localization in space and in time of the correlation, analyze its behavior for different crystal tuning angles, and underline qualitative differences with respect to type-I PDC.

Physical Review A•Jul 26, 2010•42 citations

Detection of the Ultranarrow Temporal Correlation of Twin Beams via Sum-Frequency Generation

Ottavia Jedrkiewicz, Jean-Luc Blanchet, E. Brambilla +2 more

We demonstrate the ultranarrow temporal correlation (6 fs full width half maximum) of twin beams generated by parametric down-conversion by using its reverse process, i.e., sum-frequency generation. The result relies on an achromatic imaging of a huge bandwidth of twin beams and on a careful control of their spatial degrees of freedom. The detrimental effects of spatial filtering and imperfect imaging are shown, along with the theoretical model used to describe the results.

arXiv:1203.3661•Physical Review Letters•Jun 22, 2012•27 citations

Dimensionality of the spatiotemporal entanglement of parametric down-conversion photon pairs

A. Gatti, T. Corti, E. Brambilla +1 more

In this work, the Schmidt number of the two-photon state generated by parametric down-conversion (PDC) is evaluated in the framework of a fully spatiotemporal model for PDC. A comparison with the results obtained in either purely spatial or purely temporal models shows that the degree of entanglement of the PDC state cannot be trivially reduced to the product of the Schmidt numbers obtained in models with lower dimensionality, unless the detected bandwidth is very narrow. This result is a consequence of the nonfactorability of the state in the spatial and temporal degrees of freedoms of twin photons. In the limit of a broad pump beam, we provide a geometrical interpretation of the Schmidt number as the ratio between the volume of the phase-matching region and of a correlation volume.

arXiv:1207.6932•Physical Review A•Nov 5, 2012•60 citations
In this work we propose and analyze a scheme where the full spatiotemporal correlation of twin photons or beams generated by parametric down-conversion is detected by using its inverse process, i.e., sum frequency generation. Our main result is that, by imposing independently a temporal delay \ensuremathΔt\ensuremath{\Delta}t\ensuremathΔt and a transverse spatial shift \ensuremathΔx\ensuremath{\Delta}x\ensuremathΔx between two twin components of PDC light, the up-converted light intensity provides information on the correlation of the PDC light in the full spatiotemporal domain and should enable the reconstruction of the peculiar X-shaped structure of the correlation predicted previously [A. Gatti et al. Phys. Rev. Lett. 102, 223601 (2009); L. Caspani et al. Phys. Rev. A 81, 033808 (2010); E. Brambilla et al. Phys. Rev. A 82, 013835 (2010)]. Through both a semianalytical and a numerical modeling of the proposed optical system, we analyze the feasibility of the experiment and identify the best conditions to implement it. In particular, the tolerance of the phase-sensitive measurement against the presence of dispersive elements, imperfect imaging conditions, and possible misalignments of the two crystals is evaluated.
In this paper we report about the experimental investigation of the non factorable spatio-temporal correlation of twin beams generated in parametric down conversion (PDC) at the crystal output. We present the correlation features to be reconstructed by means of the inverse process of PDC, that is sum frequency generation, in a scheme based on achromatic imaging. In particular we show the ultra-narrow temporal localization (6fs) observed thanks to the huge spectral bandwidth detected in the near field of the crystal. We illustrate the deteriorating effects of imperfect imaging conditions or spatial modes selection on the temporal correlation, giving evidence of the interdependence of spatial and temporal degrees of freedom in PDC as claimed by the theory. Throughout the paper we shall discuss about the characteristics of the experimental set-up being used for the investigation of the twin beam correlation in both the temporal and spatial domain, highlighting the important features for the success of the experiment and the demonstration of the X-shaped structure of the space-time correlation, already emerging from preliminary results.
The entangled photon pairs (biphotons) produced from parametric down-conversion (PDC) in a χ(2)crystal are the key element for several quantum information and communication schemes. Recent theoretical investigations [1–2] have revealed the peculiar structure of the biphotonic correlation characterizing the entanglement of twin beams in the space-time domain. The biphotonic correlation in type I PDC is characterized in the near field by a X-shaped geometry, which turns out to be non-factorable in space and time, offering thus the relevant possibility of manipulating the temporal bandwidth of biphoton entanglement by acting on their spatial degrees of freedom. The name “X-entanglement” was coined to describe this geometry [1]. An other key feature which emerged is the extreme spatial and temporal localization of the biphotonic correlation, on the micrometer and femtosecond range, respectively.
We investigate the spatiotemporal structure of the biphoton correlation in type-II parametric down-conversion (PDC). As in type-I PDC [Phys. Rev. Lett. 102, 223601 (2009)], we find that the correlation is nonfactorizable in space and time. Differently from type I, the type-II correlation in the spontaneous regime displays an asymmetric V-shaped structure in any cross section including time and one transverse dimension. This asymmetry along the temporal coordinate originates from the signal-idler group velocity mismatch and tends to disappear as the parametric gain is raised. We observe a progressive transition toward a symmetric X-shaped geometry similar to that found in type I when stimulated PDC becomes dominant. We also give quantitative evaluations of the localization in space and in time of the correlation, analyze its behavior for different crystal tuning angles, and underline qualitative differences with respect to type-I PDC.
In this work, the Schmidt number of the two-photon state generated by parametric down-conversion (PDC) is evaluated in the framework of a fully spatiotemporal model for PDC. A comparison with the results obtained in either purely spatial or purely temporal models shows that the degree of entanglement of the PDC state cannot be trivially reduced to the product of the Schmidt numbers obtained in models with lower dimensionality, unless the detected bandwidth is very narrow. This result is a consequence of the nonfactorability of the state in the spatial and temporal degrees of freedoms of twin photons. In the limit of a broad pump beam, we provide a geometrical interpretation of the Schmidt number as the ratio between the volume of the phase-matching region and of a correlation volume.