arXiv:1011.6417 · Physical Review B

Effect of pulse error accumulation on dynamical decoupling of the electron spins of phosphorus donors in silicon

Zhi‐Hui Wang, Wenxian Zhang, Alexei M. Tyryshkin, S. A. Lyon, Joel W. Ager, E. E. Häller, V. V. Dobrovitski

Published Feb 14, 2012• 50 citations
arXivHTMLPDF

Abstract

Dynamical decoupling (DD) is an efficient tool for preserving quantum coherence in solid-state spin systems. However, the imperfections of real pulses can ruin the performance of long DD sequences. We investigate the accumulation and compensation of different pulse errors in DD using the electron spins of phosphorus donors in silicon as a test system. We study periodic DD sequences based on spin rotations about two perpendicular axes, and their concatenated and symmetrized versions. We show that pulse errors may quickly destroy some spin states, but maintain other states with high fidelity over long times. Pulse sequences based on spin rotations about $x$ and $y$ axes outperform those based on $x$ and $z$ axes due to the accumulation of pulse errors. Concatenation provides an efficient way to suppress the impact of pulse errors, and can maintain high fidelity for all spin components: pulse errors do not accumulate (to first order) as the concatenation level increases, despite the exponential increase in the number of pulses. A symmetrized DD sequence cancels the first-order pulse errors. Our theoretical model gives a clear qualitative picture of the error accumulation and produces results in quantitative agreement with the experiments.

DOI
10.1103/physrevb.85.085206

Related papers

Aperiodic dynamical decoupling sequences in the presence of pulse errors

Zhi‐Hui Wang, V. V. Dobrovitski

Dynamical decoupling (DD) is a promising tool for preserving the quantum states of qubits. However, small imperfections in the control pulses can seriously affect the fidelity of decoupling, and qualitatively change the evolution of the controlled system at long times. Using both analytical and numerical tools, we theoretically investigate the effect of the pulse errors accumulation for two aperiodic DD sequences, the Uhrig's DD UDD) protocol [G. S. Uhrig, Phys. Rev. Lett. {\bf 98}, 100504 (2007)], and the Quadratic DD (QDD) protocol [J. R. West, B. H. Fong and D. A. Lidar, Phys. Rev. Lett {\bf 104}, 130501 (2010)]. We consider the implementation of these sequences using the electron spins of phosphorus donors in silicon, where DD sequences are applied to suppress dephasing of the donor spins. The dependence of the decoupling fidelity on different initial states of the spins is the focus of our study. We investigate in detail the initial drop in the DD fidelity, and its long-term saturation. We also demonstrate that by applying the control pulses along different directions, the performance of QDD protocols can be noticeably improved, and explain the reason of such an improvement. Our results can be useful for future implementations of the aperiodic decoupling protocols, and for better understanding of the impact of errors on quantum control of spins.

arXiv:1101.0292•Journal of Physics B Atomic Molecular and Optical Physics•Jul 25, 2011•15 citations

Dynamical Decoupling in the Presence of Realistic Pulse Errors

Alexei M. Tyryshkin, Zhi‐Hui Wang, Wenxian Zhang +4 more

One of the most significant hurdles to be overcome on the path to practical quantum information processors is dealing with quantum errors. Dynamical decoupling is a particularly promising approach that complements conventional quantum error correction by eliminating some correlated errors without the overhead of additional qubits. In practice, the control pulses used for decoupling are imperfect and thus introduce errors which can accumulate after many pulses. These instrumental errors can destroy the quantum state. Here we examine several dynamical decoupling sequences, and their concatenated variants, using electron spin resonance of donor electron spins in a $^{28}$Si crystal. All of the sequences cancel phase noise arising from slowly fluctuating magnetic fields in our spectrometer, but only those sequences based upon alternating $π$-rotations about the X- and Y-axes in the rotating frame (XYXY sequences) demonstrate the ability to store an arbitrary quantum state. By comparing the experimental results with a detailed theoretical analysis we demonstrate that the superior performance of XYXY sequences arises from the fact that they are self-correcting for the dominant instrumental pulse errors in magnetic resonance experiments. We further find that concatenated sequences perform better than the periodic variants, maintaining near 100% fidelities for spin states even after several hundred control pulses. Intuitively, one would expect the instrumental error to increase with the number of pulses in the sequence but we show that the dominant first-order error does not increase when concatenating the XYXY sequence.

arXiv:1011.1903•Nov 8, 2010•8 citations

Comparison of dynamical decoupling protocols for a nitrogen-vacancy center in diamond

Zhi‐Hui Wang, G. de Lange, Diego Ristè +2 more

We perform a detailed theoretical-experimental study of the dynamical decoupling (DD) of the nitrogen-vacancy (NV) center in diamond. We investigate the DD sequences applied to suppress the dephasing of the electron spin of the NV center induced by the coupling to a spin bath composed of the substitutional nitrogen atoms. The decoupling efficiency of various DD schemes is studied, including both periodic and aperiodic pulse sequences. For ideal control pulses, we find that the DD protocols with the Carr-Purcell-Meiboom-Gill (CPMG) timing of the pulses provides best performance. We show that, as the number of control pulses increases, the decoupling fidelity scaling differs qualitatively from the predictions of the Magnus expansion, and explain the origin of this difference. In particular, more advanced symmetrized or concatenated protocols do not improve the DD performance. Next, we investigate the impact of the systematic instrumental pulse errors in different periodic and aperiodic pulse sequences. The DD protocols with the single-axis control do not preserve all spin components in the presence of the pulse errors, and the two-axis control is needed. We demonstrate that the two-axis control sequence with the CPMG timing is very robust with respect to the pulse errors. The impact of the pulse errors can be diminished further by symmetrizing this protocol. For all protocols studied here, we present a detailed account of the pulse error parameters which make the strongest impact on the DD performance. In conclusion, we give specific recommendations about choosing the decoupling protocol for the system under investigation.

arXiv:1202.0462•Physical Review B•Apr 11, 2012•129 citations

Efficacy of noisy dynamical decoupling

Jiaan Qi, Xiansong Xu, Dario Poletti +1 more

Dynamical decoupling (DD) refers to a well-established family of methods for error mitigation, comprising pulse sequences aimed at averaging away slowly evolving noise in quantum systems. Here we revisit the question of its efficacy in the presence of noisy pulses in scenarios important for quantum devices today: pulses with gate control errors, and the computational setting where DD is used to reduce noise in every computational gate. We focus on the well-known schemes of periodic (or universal) DD and its extension, concatenated DD, for scaling up its power. The qualitative conclusions from our analysis of these two schemes nevertheless apply to other DD approaches. In the presence of noisy pulses, DD does not always mitigate errors. It does so only when the added noise from the imperfect DD pulses does not outweigh the increased ability in averaging away the original background noise. We present break-even conditions that delineate when DD is useful, and further find that there is a limit in the performance of concatenated DD, specifically in how far one can concatenate the DD pulse sequences before the added noise no longer offers any further benefit in error mitigation.

arXiv:2209.09039•Physical Review A•Mar 22, 2023•5 citations

Robust dynamical decoupling

Alexandre M. Souza, Gonzalo A. Álvarez, Dieter Suter

Quantum computers, which process information encoded in quantum mechanical systems, hold the potential to solve some of the hardest computational problems. A substantial obstacle for the further development of quantum computers is the fact that the lifetime of quantum information is usually too short to allow practical computation. A promising method for increasing the lifetime, known as dynamical decoupling (DD), consists of applying a periodic series of inversion pulses to the quantum bits. In the present review, we give an overview of this technique and compare different pulse sequences proposed earlier. We show that pulse imperfections, which are always present in experimental implementations, limit the performance of DD. The loss of coherence due to the accumulation of pulse errors can even exceed the perturbation from the environment. This effect can be largely eliminated by a judicious design of pulses and sequences. The corresponding sequences are largely immune to pulse imperfections and provide an increase of the coherence time of the system by several orders of magnitude.

arXiv:1110.6334•Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences•Sep 3, 2012•231 citations

Long-time electron spin storage via dynamical suppression of hyperfine-induced decoherence in a quantum dot

Wenxian Zhang, Nikolaos P. Konstantinidis, V. V. Dobrovitski +3 more

The coherence time of an electron spin decohered by the nuclear spin environment in a quantum dot can be substantially increased by subjecting the electron to suitable dynamical decoupling sequences. We analyze the performance of high-level decoupling protocols by using a combination of analytical and exact numerical methods, and by paying special attention to the regimes of large interpulse delays and long-time dynamics, which are outside the reach of standard average Hamiltonian theory descriptions. We demonstrate that dynamical decoupling can remain efficient far beyond its formal domain of applicability, and find that a protocol exploiting concatenated design provides best performance for this system in the relevant parameter range. In situations where the initial electron state is known, protocols able to completely freeze decoherence at long times are constructed and characterized. The impact of system and control nonidealities is also assessed, including the effect of intrabath dipolar interaction, magnetic field bias and bath polarization, as well as systematic pulse imperfections. While small bias field and small bath polarization degrade the decoupling fidelity, enhanced performance and temporal modulation result from strong applied fields and high polarizations. Overall, we find that if the relative errors of the control pulse flip angles do not exceed 3%, decoupling protocols can still prolong the coherence time by up to 2 orders of magnitude.

arXiv:0801.0992•Physical Review B•Mar 27, 2008•61 citations
Dynamical decoupling (DD) is an efficient tool for preserving quantum coherence in solid-state spin systems. However, the imperfections of real pulses can ruin the performance of long DD sequences. We investigate the accumulation and compensation of different pulse errors in DD using the electron spins of phosphorus donors in silicon as a test system. We study periodic DD sequences based on spin rotations about two perpendicular axes, and their concatenated and symmetrized versions. We show that pulse errors may quickly destroy some spin states, but maintain other states with high fidelity over long times. Pulse sequences based on spin rotations about xxx and yyy axes outperform those based on xxx and zzz axes due to the accumulation of pulse errors. Concatenation provides an efficient way to suppress the impact of pulse errors, and can maintain high fidelity for all spin components: pulse errors do not accumulate (to first order) as the concatenation level increases, despite the exponential increase in the number of pulses. A symmetrized DD sequence cancels the first-order pulse errors. Our theoretical model gives a clear qualitative picture of the error accumulation and produces results in quantitative agreement with the experiments.
Dynamical decoupling (DD) is a promising tool for preserving the quantum states of qubits. However, small imperfections in the control pulses can seriously affect the fidelity of decoupling, and qualitatively change the evolution of the controlled system at long times. Using both analytical and numerical tools, we theoretically investigate the effect of the pulse errors accumulation for two aperiodic DD sequences, the Uhrig's DD UDD) protocol [G. S. Uhrig, Phys. Rev. Lett. {\bf 98}, 100504 (2007)], and the Quadratic DD (QDD) protocol [J. R. West, B. H. Fong and D. A. Lidar, Phys. Rev. Lett {\bf 104}, 130501 (2010)]. We consider the implementation of these sequences using the electron spins of phosphorus donors in silicon, where DD sequences are applied to suppress dephasing of the donor spins. The dependence of the decoupling fidelity on different initial states of the spins is the focus of our study. We investigate in detail the initial drop in the DD fidelity, and its long-term saturation. We also demonstrate that by applying the control pulses along different directions, the performance of QDD protocols can be noticeably improved, and explain the reason of such an improvement. Our results can be useful for future implementations of the aperiodic decoupling protocols, and for better understanding of the impact of errors on quantum control of spins.
One of the most significant hurdles to be overcome on the path to practical quantum information processors is dealing with quantum errors. Dynamical decoupling is a particularly promising approach that complements conventional quantum error correction by eliminating some correlated errors without the overhead of additional qubits. In practice, the control pulses used for decoupling are imperfect and thus introduce errors which can accumulate after many pulses. These instrumental errors can destroy the quantum state. Here we examine several dynamical decoupling sequences, and their concatenated variants, using electron spin resonance of donor electron spins in a 28^{28}28Si crystal. All of the sequences cancel phase noise arising from slowly fluctuating magnetic fields in our spectrometer, but only those sequences based upon alternating πππ-rotations about the X- and Y-axes in the rotating frame (XYXY sequences) demonstrate the ability to store an arbitrary quantum state. By comparing the experimental results with a detailed theoretical analysis we demonstrate that the superior performance of XYXY sequences arises from the fact that they are self-correcting for the dominant instrumental pulse errors in magnetic resonance experiments. We further find that concatenated sequences perform better than the periodic variants, maintaining near 100% fidelities for spin states even after several hundred control pulses. Intuitively, one would expect the instrumental error to increase with the number of pulses in the sequence but we show that the dominant first-order error does not increase when concatenating the XYXY sequence.
We perform a detailed theoretical-experimental study of the dynamical decoupling (DD) of the nitrogen-vacancy (NV) center in diamond. We investigate the DD sequences applied to suppress the dephasing of the electron spin of the NV center induced by the coupling to a spin bath composed of the substitutional nitrogen atoms. The decoupling efficiency of various DD schemes is studied, including both periodic and aperiodic pulse sequences. For ideal control pulses, we find that the DD protocols with the Carr-Purcell-Meiboom-Gill (CPMG) timing of the pulses provides best performance. We show that, as the number of control pulses increases, the decoupling fidelity scaling differs qualitatively from the predictions of the Magnus expansion, and explain the origin of this difference. In particular, more advanced symmetrized or concatenated protocols do not improve the DD performance. Next, we investigate the impact of the systematic instrumental pulse errors in different periodic and aperiodic pulse sequences. The DD protocols with the single-axis control do not preserve all spin components in the presence of the pulse errors, and the two-axis control is needed. We demonstrate that the two-axis control sequence with the CPMG timing is very robust with respect to the pulse errors. The impact of the pulse errors can be diminished further by symmetrizing this protocol. For all protocols studied here, we present a detailed account of the pulse error parameters which make the strongest impact on the DD performance. In conclusion, we give specific recommendations about choosing the decoupling protocol for the system under investigation.
Dynamical decoupling (DD) refers to a well-established family of methods for error mitigation, comprising pulse sequences aimed at averaging away slowly evolving noise in quantum systems. Here we revisit the question of its efficacy in the presence of noisy pulses in scenarios important for quantum devices today: pulses with gate control errors, and the computational setting where DD is used to reduce noise in every computational gate. We focus on the well-known schemes of periodic (or universal) DD and its extension, concatenated DD, for scaling up its power. The qualitative conclusions from our analysis of these two schemes nevertheless apply to other DD approaches. In the presence of noisy pulses, DD does not always mitigate errors. It does so only when the added noise from the imperfect DD pulses does not outweigh the increased ability in averaging away the original background noise. We present break-even conditions that delineate when DD is useful, and further find that there is a limit in the performance of concatenated DD, specifically in how far one can concatenate the DD pulse sequences before the added noise no longer offers any further benefit in error mitigation.
Quantum computers, which process information encoded in quantum mechanical systems, hold the potential to solve some of the hardest computational problems. A substantial obstacle for the further development of quantum computers is the fact that the lifetime of quantum information is usually too short to allow practical computation. A promising method for increasing the lifetime, known as dynamical decoupling (DD), consists of applying a periodic series of inversion pulses to the quantum bits. In the present review, we give an overview of this technique and compare different pulse sequences proposed earlier. We show that pulse imperfections, which are always present in experimental implementations, limit the performance of DD. The loss of coherence due to the accumulation of pulse errors can even exceed the perturbation from the environment. This effect can be largely eliminated by a judicious design of pulses and sequences. The corresponding sequences are largely immune to pulse imperfections and provide an increase of the coherence time of the system by several orders of magnitude.
The coherence time of an electron spin decohered by the nuclear spin environment in a quantum dot can be substantially increased by subjecting the electron to suitable dynamical decoupling sequences. We analyze the performance of high-level decoupling protocols by using a combination of analytical and exact numerical methods, and by paying special attention to the regimes of large interpulse delays and long-time dynamics, which are outside the reach of standard average Hamiltonian theory descriptions. We demonstrate that dynamical decoupling can remain efficient far beyond its formal domain of applicability, and find that a protocol exploiting concatenated design provides best performance for this system in the relevant parameter range. In situations where the initial electron state is known, protocols able to completely freeze decoherence at long times are constructed and characterized. The impact of system and control nonidealities is also assessed, including the effect of intrabath dipolar interaction, magnetic field bias and bath polarization, as well as systematic pulse imperfections. While small bias field and small bath polarization degrade the decoupling fidelity, enhanced performance and temporal modulation result from strong applied fields and high polarizations. Overall, we find that if the relative errors of the control pulse flip angles do not exceed 3%, decoupling protocols can still prolong the coherence time by up to 2 orders of magnitude.