arXiv:1003.1485 · Physics Letters A

Microwave diagnostics of ultracold neutral plasma

Ronghua Lu, Li Shuai Guo, Jingwei Guo, Shensheng Han

Published Apr 25, 2011• 5 citations
arXivHTMLPDF
DOI
10.1016/j.physleta.2011.04.027

Related papers

Microwave diagnostic of ultracold neutral plasma

陆荣华, Liguo, 郭敬为 +1 more

•Jan 1, 2011•0 citations

Plasma Oscillation Damping in an Ultracold Neutral Plasma

Wei‐Ting Chen, Craig Witte, Jacob Roberts

Bulletin of the American Physical Society•Jun 3, 2014•1 citation

Ultracold Plasma Electron Temperature Measurements using Collective Mode Diagnostics

Robert Samuel Fletcher, Xianli Zhang, S. L. Rolston

Bulletin of the American Physical Society•Nov 3, 2006•0 citations

Design and characterization of a resonant microwave cavity as a diagnostic for ultracold plasmas

M. A. W. van Ninhuijs, K. A. Daamen, Job Beckers +1 more

We present the design and commissioning of a resonant microwave cavity as a novel diagnostic for the study of ultracold plasmas. This diagnostic is based on the measurements of the shift in the resonance frequency of the cavity, induced by an ultracold plasma that is created from a laser-cooled gas inside. This method is simultaneously non-destructive, very fast (nanosecond temporal resolution), highly sensitive, and applicable to all ultracold plasmas. To create an ultracold plasma, we implement a compact magneto-optical trap based on a diffraction grating chip inside a 5 GHz resonant microwave cavity. We are able to laser cool and trap (7.25 ± 0.03) × 107 rubidium atoms inside the cavity, which are turned into an ultracold plasma by two-step pulsed (nanosecond or femtosecond) photo-ionization. We present a detailed characterization of the cavity, and we demonstrate how it can be used as a fast and sensitive probe to monitor the evolution of ultracold plasmas non-destructively. The temporal resolution of the diagnostic is determined by measuring the delayed frequency shift following femtosecond photo-ionization. We find a response time of 18 ± 2 ns, which agrees well with the value determined from the cavity quality factor and resonance frequency.

Review of Scientific Instruments•Jan 1, 2021•7 citations

Dynamics of ultracold neutral plasma

Lee A. Collins, Byoungseon Jeon, Joel D. Kress +1 more

Bulletin of the American Physical Society•Mar 7, 2007•0 citations

Collisional microwave heating and wall interaction of an ultracold plasma in a resonant microwave cavity

M. A. W. van Ninhuijs, Job Beckers, O.J. Luiten

Abstract Recently, we introduced a resonant microwave cavity as a diagnostic tool for the study of ultracold plasmas (UCPs). This diagnostic allows us to study the electron dynamics of UCPs non-destructively, very fast, and with high sensitivity by measuring the shift in the resonance frequency of a cavity, induced by a plasma. However, in an attempt to theoretically predict the frequency shift using a Gaussian self-similar expansion model, a three times faster plasma decay was observed in the experiment than found in the model. For this, we proposed two causes: plasma–wall interactions and collisional microwave heating. In this paper, we investigate the effect of both causes on the lifetime of the plasma. We present a simple analytical model to account for electrons being lost to the cavity walls. We find that the model agrees well with measurements performed on plasmas with different initial electron temperatures and that the earlier discrepancy can be attributed to electrons being lost to the walls. In addition, we perform measurements for different electric field strengths in the cavity and find that the electric field has a small, but noticeable effect on the lifetime of the plasma. By extending the model with the theory of collisional microwave heating, we find that this effect can be predicted quite well by treating the energy transferred from the microwave field to the plasma as additional initial excess energy for the electrons.

New Journal of Physics•Jun 1, 2022•4 citations
We present the design and commissioning of a resonant microwave cavity as a novel diagnostic for the study of ultracold plasmas. This diagnostic is based on the measurements of the shift in the resonance frequency of the cavity, induced by an ultracold plasma that is created from a laser-cooled gas inside. This method is simultaneously non-destructive, very fast (nanosecond temporal resolution), highly sensitive, and applicable to all ultracold plasmas. To create an ultracold plasma, we implement a compact magneto-optical trap based on a diffraction grating chip inside a 5 GHz resonant microwave cavity. We are able to laser cool and trap (7.25 ± 0.03) × 107 rubidium atoms inside the cavity, which are turned into an ultracold plasma by two-step pulsed (nanosecond or femtosecond) photo-ionization. We present a detailed characterization of the cavity, and we demonstrate how it can be used as a fast and sensitive probe to monitor the evolution of ultracold plasmas non-destructively. The temporal resolution of the diagnostic is determined by measuring the delayed frequency shift following femtosecond photo-ionization. We find a response time of 18 ± 2 ns, which agrees well with the value determined from the cavity quality factor and resonance frequency.
Abstract Recently, we introduced a resonant microwave cavity as a diagnostic tool for the study of ultracold plasmas (UCPs). This diagnostic allows us to study the electron dynamics of UCPs non-destructively, very fast, and with high sensitivity by measuring the shift in the resonance frequency of a cavity, induced by a plasma. However, in an attempt to theoretically predict the frequency shift using a Gaussian self-similar expansion model, a three times faster plasma decay was observed in the experiment than found in the model. For this, we proposed two causes: plasma–wall interactions and collisional microwave heating. In this paper, we investigate the effect of both causes on the lifetime of the plasma. We present a simple analytical model to account for electrons being lost to the cavity walls. We find that the model agrees well with measurements performed on plasmas with different initial electron temperatures and that the earlier discrepancy can be attributed to electrons being lost to the walls. In addition, we perform measurements for different electric field strengths in the cavity and find that the electric field has a small, but noticeable effect on the lifetime of the plasma. By extending the model with the theory of collisional microwave heating, we find that this effect can be predicted quite well by treating the energy transferred from the microwave field to the plasma as additional initial excess energy for the electrons.