Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1002.2311 · New Journal of Physics

Imaging a single atom in a time-of-flight experiment

Andreas Fuhrmanek, Andrew M. Lance, Charles Tuchendler, Philippe Grangier, Yvan R. P. Sortais, Antoine Browaeys

Published May 18, 2010• 57 citations
arXivHTMLPDF

Abstract

We perform fluorescence imaging of a single 87 Rb atom after its release from an optical dipole trap. The time-of-flight expansion of the atomic spatial density distribution is observed by accumulating many single atom images. The position of the atom is revealed with a spatial resolution close to 1 μm by a single-photon event, induced by a short resonant probe. The expansion yields a measure of the temperature of a single atom, which is in very good agreement with the value obtained by an independent measurement based on a release-and-recapture method. The analysis presented in this paper provides a way of calibrating an imaging system useful for experimental studies involving a few atoms confined in a dipole trap.

DOI
10.1088/1367-2630/12/5/053028

Related papers

Measurement of the atom number distribution in an optical tweezer using single-photon counting

Andreas Fuhrmanek, Yvan R. P. Sortais, Philippe Grangier +1 more

We demonstrate in this paper a method to reconstruct the atom number distribution of a cloud containing a few tens of cold atoms. The atoms are first loaded from a magneto-optical trap into a microscopic optical dipole trap and then released in a resonant light probe where they undergo a Brownian motion and scatter photons. We count the number of photon events detected on an image intensifier. Using the response of our detection system to a single atom as a calibration, we extract the atom number distribution when the trap is loaded with more than one atom. The atom number distribution is found to be compatible with a Poisson distribution.

arXiv:1006.0917•Physical Review A•Aug 30, 2010•24 citations

Imaging-based parametric resonance in an optical dipole-atom trap

Salim Balik, Aye Win, Mark D. Havey

We report sensitive detection of parametric resonances in a high-density sample of ultracold $^{87}\text{R}\text{b}$ atoms confined to a far-off-resonance optical dipole trap. Fluorescence imaging of the expanded ultracold atom cloud after a period of parametric excitation shows significant modification of the atomic spatial distribution and has high sensitivity compared with traditional measurements of parametrically driven trap loss. Using this approach, a significant shift of the parametric resonance frequency is observed and attributed to the anharmonic shape of the dipole trap potential.

arXiv:0908.0263•Physical Review A•Aug 6, 2009•17 citations

Fluorescence imaging efficiency of cold atoms in free fall

Isabelle Serre, Laurence Pruvost, H. T. Duong

A fluorescence detection scheme coupled to a highly sensitive nitrogen-cooled CCD camera is used to image the spatial distribution of a low-density falling rubidium atomic cloud released from an optical trap. The falling cloud passes through a thin probe laser beam tuned to resonance. The performance of the scheme is illustrated in the analysis of cold atomic clouds collimated by pinholes during their free fall under the influence of gravity. Clouds of approximately 10(4) atoms and with typically 10(6) at./cm(3) density are analyzed spatially with 24-mum resolution. This method is compared with different atomic cloud imaging techniques.

Applied Optics•Feb 20, 1998•7 citations

Single-particle-sensitive imaging of freely propagating ultracold atoms

Robert Bücker, A. Perrin, Stephanie Manz +6 more

We present a novel imaging system for ultracold quantum gases in expansion. After release from a confining potential, atoms fall through a sheet of resonant excitation laser light and the emitted fluorescence photons are imaged onto an amplified CCD camera using a high numerical aperture optical system. The imaging system reaches an extraordinary dynamic range, not attainable with conventional absorption imaging. We demonstrate single-atom detection for dilute atomic clouds with high efficiency where at the same time dense Bose-Einstein condensates can be imaged without saturation or distortion. The spatial resolution can reach the sampling limit as given by the 8 μm pixel size in object space. Pulsed operation of the detector allows for slice images, a first step toward a 3D tomography of the measured object. The scheme can easily be implemented for any atomic species and all optical components are situated outside the vacuum system. As a first application we perform thermometry on rubidium Bose-Einstein condensates created on an atom chip.

arXiv:0907.0674•New Journal of Physics•Oct 21, 2009•132 citations

Measurement of temperature of laser cooled atoms by one-dimensional expansion in a magneto-optical trap

Swarupananda Pradhan, B. N. Jagatap

We discuss a simple time of flight technique for measurement of temperature of a cold cloud in a magneto-optical trap (MOT). The technique is based on spatiotemporal fluorescence imaging of the cloud that is allowed to undergo one-dimensional expansion in the presence of the orthogonal two-dimensional configuration of laser beams by temporal modulation of a pair of counterpropagating trapping beams in the MOT. We show that, in the time scale 0< or =t<5 ms, the expansion of the cloud is ballistic and the temperature can be extracted from the time variation of the rms size of the cloud in the expansion direction. The reliability of the technique has been established by comparing the results with release and recapture method, and also by fitting them to the known temperature scaling law.

Review of Scientific Instruments•Jan 1, 2008•18 citations

Studies on cold atoms trapped in a Quasi-Electrostatic optical dipole trap

Sanjukta Roy, Saptarishi Chaudhuri, C. S. Unnikrishnan

We discuss the results of measurements of the temperature and density distribution of cold Rubidium atoms trapped and cooled in an optical dipole trap formed by focussed CO 2 laser beams at a wavelength of 10.6 μ m from a cold, collimated and intense atomic beam of flux 2 × 10 10 atoms/s produced using an elongated 2D + MOT. A large number of rubidium atoms (⩾ 10 10 ) were trapped in the MOT and the number density of atoms were further increased by making a temporal dark MOT to prevent density-limiting processes like photon rescattering by atoms at the trap centre. Subsequently, between 10 7 to 10 8 cold atoms at a temperature below 30 μK were transferred into a Quasi-Electrostatic trap (QUEST) formed by focussed CO 2 laser beams at the MOT centre. Both single beam and crossed dual beam dipole traps were studied with a total output power of 50 W from the CO 2 laser with focal spot sizes less than 100 microns. Various measurements were done on the cold atoms trapped in the dipole trap. The total atom number in the dipole trap and the spatial atom number density distribution in the trap was measured by absorption imaging technique. The temperature was determined from time-of-flight (TOF) data as well as from the absorption images after ballistic expansion of the atom cloud released from the dipole trap. The results from measurements are used to maximize the initial phase-space density prior to forced evaporative cooling to produce a Bose-Einstein Condensate.

Journal of Physics Conference Series•Sep 1, 2007•2 citations
We perform fluorescence imaging of a single 87 Rb atom after its release from an optical dipole trap. The time-of-flight expansion of the atomic spatial density distribution is observed by accumulating many single atom images. The position of the atom is revealed with a spatial resolution close to 1 μm by a single-photon event, induced by a short resonant probe. The expansion yields a measure of the temperature of a single atom, which is in very good agreement with the value obtained by an independent measurement based on a release-and-recapture method. The analysis presented in this paper provides a way of calibrating an imaging system useful for experimental studies involving a few atoms confined in a dipole trap.
We demonstrate in this paper a method to reconstruct the atom number distribution of a cloud containing a few tens of cold atoms. The atoms are first loaded from a magneto-optical trap into a microscopic optical dipole trap and then released in a resonant light probe where they undergo a Brownian motion and scatter photons. We count the number of photon events detected on an image intensifier. Using the response of our detection system to a single atom as a calibration, we extract the atom number distribution when the trap is loaded with more than one atom. The atom number distribution is found to be compatible with a Poisson distribution.
We report sensitive detection of parametric resonances in a high-density sample of ultracold 87Rb^{87}\text{R}\text{b}87Rb atoms confined to a far-off-resonance optical dipole trap. Fluorescence imaging of the expanded ultracold atom cloud after a period of parametric excitation shows significant modification of the atomic spatial distribution and has high sensitivity compared with traditional measurements of parametrically driven trap loss. Using this approach, a significant shift of the parametric resonance frequency is observed and attributed to the anharmonic shape of the dipole trap potential.
A fluorescence detection scheme coupled to a highly sensitive nitrogen-cooled CCD camera is used to image the spatial distribution of a low-density falling rubidium atomic cloud released from an optical trap. The falling cloud passes through a thin probe laser beam tuned to resonance. The performance of the scheme is illustrated in the analysis of cold atomic clouds collimated by pinholes during their free fall under the influence of gravity. Clouds of approximately 10(4) atoms and with typically 10(6) at./cm(3) density are analyzed spatially with 24-mum resolution. This method is compared with different atomic cloud imaging techniques.
We present a novel imaging system for ultracold quantum gases in expansion. After release from a confining potential, atoms fall through a sheet of resonant excitation laser light and the emitted fluorescence photons are imaged onto an amplified CCD camera using a high numerical aperture optical system. The imaging system reaches an extraordinary dynamic range, not attainable with conventional absorption imaging. We demonstrate single-atom detection for dilute atomic clouds with high efficiency where at the same time dense Bose-Einstein condensates can be imaged without saturation or distortion. The spatial resolution can reach the sampling limit as given by the 8 μm pixel size in object space. Pulsed operation of the detector allows for slice images, a first step toward a 3D tomography of the measured object. The scheme can easily be implemented for any atomic species and all optical components are situated outside the vacuum system. As a first application we perform thermometry on rubidium Bose-Einstein condensates created on an atom chip.
We discuss a simple time of flight technique for measurement of temperature of a cold cloud in a magneto-optical trap (MOT). The technique is based on spatiotemporal fluorescence imaging of the cloud that is allowed to undergo one-dimensional expansion in the presence of the orthogonal two-dimensional configuration of laser beams by temporal modulation of a pair of counterpropagating trapping beams in the MOT. We show that, in the time scale 0< or =t<5 ms, the expansion of the cloud is ballistic and the temperature can be extracted from the time variation of the rms size of the cloud in the expansion direction. The reliability of the technique has been established by comparing the results with release and recapture method, and also by fitting them to the known temperature scaling law.
We discuss the results of measurements of the temperature and density distribution of cold Rubidium atoms trapped and cooled in an optical dipole trap formed by focussed CO 2 laser beams at a wavelength of 10.6 μ m from a cold, collimated and intense atomic beam of flux 2 × 10 10 atoms/s produced using an elongated 2D + MOT. A large number of rubidium atoms (⩾ 10 10 ) were trapped in the MOT and the number density of atoms were further increased by making a temporal dark MOT to prevent density-limiting processes like photon rescattering by atoms at the trap centre. Subsequently, between 10 7 to 10 8 cold atoms at a temperature below 30 μK were transferred into a Quasi-Electrostatic trap (QUEST) formed by focussed CO 2 laser beams at the MOT centre. Both single beam and crossed dual beam dipole traps were studied with a total output power of 50 W from the CO 2 laser with focal spot sizes less than 100 microns. Various measurements were done on the cold atoms trapped in the dipole trap. The total atom number in the dipole trap and the spatial atom number density distribution in the trap was measured by absorption imaging technique. The temperature was determined from time-of-flight (TOF) data as well as from the absorption images after ballistic expansion of the atom cloud released from the dipole trap. The results from measurements are used to maximize the initial phase-space density prior to forced evaporative cooling to produce a Bose-Einstein Condensate.