We report on the successful implementation of an approach to locking the frequencies of an optical parametric oscillator (OPO)-based squeezed-vacuum source and its driving laser. The technique allows the simultaneous measurement of the phase shifts induced by a cavity, which may be used for the purposes of frequency locking, as well as the simultaneous measurement of the sub-quantum-noise-limited (sub-QNL) phase quadrature output of the OPO. The homodyne locking technique is cheap, easy to implement, and has the distinct advantage that subsequent homodyne measurements are automatically phase locked. The homodyne locking technique is also unique in that it is a sub-QNL frequency discriminator.
We report on the successful implementation of an approach to locking the frequencies of an optical parametric oscillator (OPO)-based squeezed-vacuum source and its driving laser. The technique allows the simultaneous measurement of the phase shifts induced by a cavity, which may be used for the purposes of frequency locking, as well as the simultaneous measurement of the sub-quantum-noise-limited (sub-QNL) phase quadrature output of the OPO. The homodyne locking technique is cheap, easy to implement, and has the distinct advantage that subsequent homodyne measurements are automatically phase locked. The homodyne locking technique is also unique in that it is a sub-QNL frequency discriminator.
Squeezed states are important sources in quantum physics, which have potential applications in fields such as quantum teleportation, quantum information networks, quantum memory, and quantum metrology and precise measurements. For our interest, the squeezed vacuum will be used in the quantum-enhanced optical atomic magnetometers, filling the vacuum port of the probe beam to improve measurement sensitivity. Based on the sub-threshold optical parametric oscillator (OPO) with PPKTP crystal, the squeezed vacuum at rubidium D1 line of 795 nm is obtained. In our work, we investigate the noise sources in an OPO system. By carefully controlling the classical noise source, the squeezing band extends to the analysis frequency of 2.6 kHz. The flat squeezing trace is 2.8 dB below the shot noise limit. In our work, we focus on the difference between the squeezing results at the analysis frequency of kilohertz regime at two different wavelengths, 1064 nm and 795 nm. The difference mainly comes from the absorption of 795 nm laser and its second harmonic at 397.5 nm in crystal (397.5 nm laser is at the edge of transparent window of PPKTP crystal that has an absorption index much higher than at other wavelength). The absorption induced nonlinear loss and thermal instability greatly affect the squeezing results, which is discussed in our work. Squeezing level at 795 nm is worse than at 1064 nm due to the above-mentioned factors. Noise coupling to the detection system limits the squeezing band. In the audio frequency band, squeezing is easily submerged in roll-up noises and the measured squeezing level is limited. Two factors limit the obtained squeezing:the technical noise induced in the detection and the squeezing degradation by the noise coupling of the control beams. In experiment, we carefully control the classical noise at analytical frequency of kilohertz by means of a vacuum-injected OPO, a counter-propagating cavity locking beam with orthogonal polarization, low noise homodyne detector, stable experimental system and quantum noise locking method for squeezing phase locking. Firstly, to preclude the classical noise from coupling the laser source, we use the vacuum injected OPO. A signal beam helps optimize the parametric gain and is blocked in the squeezing measurement process. In order to maintain the OPO, a counter-propagating beam with orthogonal polarization is used for locking the cavity. Then, a low noise balanced homodyne detector with a common-mode rejection ratio of 45 dB helps improve the audio frequency detection. Finally, the quantum noise locking provides a method to lock the relative phase between the coherent beam and the squeezed vacuum field. With the combination of these technical improvements, a squeezed vacuum of 2.8 dB is obtained at the analysis frequency of 2.6-100 kHz. The obtained squeezing level is mainly limited by the relatively large loss in OPO, which is induced by ultra-violet absorption in PPKTP crystal. The generated squeezed field is used to reduce the polarization noise of probe beam in an optical magnetometer, in order to increase detection sensitivity.
We report the experimental generation of a squeezed vacuum at frequencies ranging from 2.5 kHz to 200 kHz that is resonant on the cesium D2 line by using a below-threshold optical parametric oscillator (OPO). The OPO is based on a periodically-poled KTiOPO 4 (PPKTP) crystal that is pumped using a bow-tie four-mirror ring frequency doubler. The phase of the squeezed light is controlled using a quantum noise locking technique. At a pump power of 115 mW, maximum quadrature phase squeezing of 3.5 dB and anti-squeezing of 7.5 dB are detected using a home-made balanced homodyne detector. This squeezed vacuum at an atomic transition in the kilohertz range is an ideal quantum source for quantum metrology of enhancing measurement precision, especially for ultra-sensitive measurement of weak magnetic fields when using a Cs atomic magnetometer in the audio frequency range.
In high-precision optical measurements, squeezed vacuum states are a promising resource for reducing the shot noise. To utilize a squeezed vacuum, it is important to lock the phase of the local oscillator (LO) to the squeezed light. The coherent control sideband (CCSB) scheme has been established for the precise phase locking, while the previous CCSB scheme was designed for the squeezed vacuum generated with an optical parametric oscillator (OPO). Thus the previous CCSB scheme is not applicable to squeezing by a single-pass optical parametric amplifier (OPA), which is attractive for generating broadband squeezed vacuum states. In this study, we propose a variant of CCSB scheme, which is applicable to the squeezing by single-pass OPA. In this scheme, we inject pump light and frequency-shifted signal light into an OPA crystal in the same way as the previous CCSB scheme. The parametric process in the OPA crystal generates a squeezed vacuum, amplifies the signal light, generates an idler light, and causes the pump depletion reflecting the interference of the amplified signal light and the idler light. Through the lock-in detection of the pump depletion, we can phase-lock the injected signal light to the pump light. Then, after the heterodyne detection of the signal and the idler light, we get the error signal of LO and realize the precise phase locking of LO to the squeezed quadrature. We show the feasibility of the proposed scheme by deriving the signal-to-noise ratio (SNR) of the modulated pump signal. We experimentally demonstrate the proposed scheme on pulsed squeezing by a single-pass OPA.
Squeezed state of light is an important resource of optical measuerments below the shot noise limit and has been used to improve measurement sensitivity in many areas such as gravitational wave detection, especially in audio frequency region. Compared with the high-frequency squeezed states, the generation of the low-frequency squeezed states is more difficult, because it is limited by several technical noise sources. In this paper we report the observation of more than 2 dB of vacuum squeezing at 1064 nm in the gravitational-wave detection band down to 3 kHz with a double-resonant optical parametric oscillator (OPO). The OPO has a configuration of linear cavity consisting of an input coupling mirror with a transmission of 11% at 532 nm and an output coupling mirror with the transmission of 12% at 1064 nm. The nonlinear materials in the OPO is type-I periodically poled potassium titanyl phosphate (PPKTP) crystal which is chosen for this experiment due to its higher nonlinearity, broader phase matching temperature, and smaller photo-thermal effect. The OPO is pumped by the light of 532 nm from Nd: YVO4/KTP solid-state laser of maximum optical power 3 W. To avoid various noise coupled from the seed beam, the OPO is seeded by vacuum fluctuations instead of coherent field at the fundamental wavelength (1064 nm). A Pound-Drever-Hall (PDH) locking scheme is used to lock the OPO cavity length with the signal derived from the reflected pump beam, so as to lock the pump field and also lock the fundamental field. To make both the pump and seed beams resonant simultaneously, the temperature of the PPKTP is carefully adjusted. The squeezed state can be detected on a homodyne detection by interfering it with the local oscillator (LO) and detected by a balanced detector with two photodiodes (EXT500 T) but having the same quantum efficiency of 86% at 1064 nm. The subsequent electronic noise is analyzed with a low-frequency spectrum analyzer, which shows that the audio noise sources from lab enviroment, locking quality, escape efficiency, propagation loss, homodyne efficiency and detection efficiency have effect on the squeezing pruced by an OPO.
Squeezed vacuum states were generated using a subthreshold optical parametric oscillator (OPO) and a home-made, continuous-wave, single-frequency 532 nm and 1064 nm dual-wavelength laser. The OPO was pumped by the 532 nm output of the laser. The 1064 nm output of the laser was used to generate an auxiliary beam by optical serrodyne sideband modulation and a coherent control field (CCF). When the subthreshold OPO was locked using the auxiliary beam and the squeezing angle controlled using the CCF, 6.1 ± 0.3 dB phase-squeezed vacuum states at audio frequencies from 5 to 100 kHz were stably generated with a compact configuration.