arXiv:0906.4563 · Optics Express

On the application of a monolithic array for detecting intensity-correlated photons emitted by different source types

D. L. Boïko, Neil J. Günther, N. Brauer, M. Sergio, C. Niclass, G. B. Beretta, Edoardo Charbon A

Published Aug 11, 2009• 6 citations
arXivHTMLPDF

Abstract

It is not widely appreciated that many subtleties are involved in the accurate measurement of intensity-correlated photons; even for the original experiments of Hanbury Brown and Twiss (HBT). Using a monolithic 4 x 4 array of single-photon avalanche diodes (SPADs), together with an off-chip algorithm for processing streaming data, we investigate the difficulties of measuring second-order photon correlations g((2))(x(iota), t(iota),x, t) in a wide variety of light fields that exhibit dramatically different correlation statistics: a multimode He-Ne laser, an incoherent intensity-modulated lamp-light source and a thermal light source. Our off-chip algorithm treats multiple photon-arrivals at pixel-array pairs, in any observation interval, with photon fluxes limited by detector saturation, in such a way that a correctly normalized g((2)) function is guaranteed. The impact of detector background correlations between SPAD pixels and afterpulsing effects on second-order coherence measurements is discussed. These results demonstrate that our monolithic SPAD array enables access to effects that are otherwise impossible to measure with stand-alone detectors.

DOI
10.1364/oe.17.015087

Related papers

Experiments supporting the concept of a g(2)-camera

D. L. Boïko, Neil J. Günther, Maximilian Sergio +3 more

It is well known that totally incoherent light cannot exhibit first-order with photons that are uncorrelated, i.e., the normalized first-order correlation function is g(1)(0) = 0, whereas the second-order correlation function is g(2)(0) = 1. Less familiar is the fact that both chaotic and coherent sources can exhibit first-order interference, so that merely using the term interference is ambiguous. If fact, some previous QIQC presentations have centered around whether or not two-photon correlations are actually a form of two-photon interference.1 Another area of ambiguity concerns the detection of quantum state coherence using interference.2 In an attempt to disambiguate the concept of interference, we examine associated photon states using chaotic sources and the Hanbury Brown and Twiss (HBT) detection of bunched photons. The unambiguous determination of coherent quantum states has important applications for: (1) Atomic Bose-Einstein condensate (BEC) determined using scattered laser interference3 (2) Exciton-Polariton BEC determined using emitted photon interference4 (3) Coherent light states. (4) Characterizing photon statistics. (5) Characterization of extended sources. In this paper, we present imaging results for topics 3-5. The difficulties of HBT data acquisition are generally underappreciated. An advantage of our approach is super-linear speedup through the development of a new imaging device consisting of a 2-dimensional array of single-photon avalanche detectors.5, 6 A 4 × 4 array enables 120 HBT coincidence experiments to be run in parallel to generate the 2-dimensional distribution of g(2)(x) spatial correlations, thus making plausible the term g2 camera for this quantum imaging device.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 28, 2008•0 citations

A new method to measure true two-photoncorrelation of soft X-ray synchrotronradiation

Renzhong Tai

Two-photon correlation measurement provides a promising way to experimentally demonstrate the statistical nature of a light source, which is very significant for the deep understanding of the photon-generating process and the diagnosing of the coherence property. Quantitatively two- photon correlation is described by second-order coherence. Usually the behavior of the second-order coherence against any of the parameters defining the phase volume is different for different photon statistics. The Poisson photon statistics for coherent light gives its second-order coherence as a flat response; The Bose-Einstein photon statistics for chaotic light gives its second-order coherence as a bunching effect; While the Sub-Poisson photon statistics for non-classical light gives its second-order coherence as an anti-bunching effect. Therefore the measurement of two-photon correlation is proved to be a good finger print to check whether light is in coherent state or incoherent state such as thermal state or non-classical state. Historically the measurement of two-photon correlation was first performed by Hanbury-Brown and Twiss (HBT) in 1956. They used a linear mixer to realize the correlation of the two currents from the photoelectric detectors illuminated by a stationary thermal light souece, a mercury arc, and the photo-bunching effect was first successfully observed in the visible region of 435.8 nm. HBT method is no doubt a good way to extract the small excess two-photon correlation for a stationary light because the background, that is the DC components, has been cut off automatically by the broad band amplifiers, which is in fact the key of the success of HBT experiment. However there exists a general problem, to which no attention has ever been paid, in measuring the two-photon correlation of non-stationary light such as synchrotron radiation (SR) by the HBT method. Here the "non-stationary" means a sense of classical mechanics that the observed intensity has some deterministic time structure. The systematic time structure of SR decided by the bunch distribution of the electric current in a storage ring will give rise to a large amount of unexpected accidental correlation, which in fact has nothing to do with the inherent photon statistics of light source and usually l000~l0000 times larger than the true two-photon correlation due to the short bunch separation length (2ns) and the short coherence time (~0.1ps) which is not comparable to the time resolution (1ns) of the measuring system. The existence of the accidental correlation would severely prevent us from observing the bunching effect of the true two-photon correlation. Therefore to suppress the much larger accidental correlation and to extract the small true two-photon correlation, a novel intensity interferometer has been developed for soft X-ray synchrotron radiation. This intensity interferometer consists of an optical vacuum chamber and an electric correlator. All the essential optical elements which includes a wire scanner, a precise diffraction slit, a grating monochromator with a coherence time modulator, a beam divider and two fast-response photon detectors (microchannel plates) are mounted in this high vacuum chamber. The electric correlator completes the multiplication of the two broad band electric currents coming from the photoelectric detectors. The basic idea to suppress the much larger accidental correlation is to modulate the coherence time by modulating the entrance slit width of the monochromator by a piezoclectric translator. The two sets of light intensity are simultaneously modulated too. When the frequency of modulation is f, the third harmonics 3f is detected with a loch-in amplifier because the 3f components include only the true two-photon correlation. Practically it is difficult to modulate with frequency f without any higher order harmonics distortion which might add some false 3f components. To overcome this difficulty we have used a sharp bandpass filter of l00~350 MHz in each branch of the correlator, which is lower than the RF frequency 500 MHz and much higher than 1.6 MHz, the revolution frequency of the stored beam of the 2.5 GeV storage ring. This new apparatus has been operated successfully in the measurement of the horizontal two-photon correlation for the first harmonic of undulator radiation with photon energy of 70 eV at the Photon Factory, KEK. By narrowing the precise slit width which correspondingly changes the spatial coherence of the incident SR, a bunching effect of the normalized excess two-photon correlation has been clearly observed. This explicit bunching effect implies that synchrotron radiation is chaotic radiation. Further investigation shows that although second-order coherence is completely determined by the first-order coherence for the case of chaotic light, the measured information from the light source is essentially different. The two-photon correlation of synchrotron radiation does not depend on the response time of the detectors but gives the information of instantaneous emittance of the stored beam with the time scale of coherence time τC. By fitting the experimental data, the horizontal instantaneous emittance of the stored beam is estimated to be 40nmrad. This intensity interferometer can be utilized to characterize the coherence properties of incomplete FELs, such as SASE, because if they are fully coherent light sources the normalized excess two-photon correlation would have a flat response, but not showing a photon-bunching effect.

•Mar 24, 1999•0 citations

Analysis and measurement of high-order photon correlations of light fields

Yanqiang Guo, Lijing Wang, Yu Wang +3 more

High-order photon correlations of light fields are important for characterizing the quantum nature. Since Hanbury Brown and Twiss conducted the pioneering experiments in the 1950s, the HBT effect has inspired extensive research on high-order photon correlation in quantum optics, quantum information, and quantum imaging. The Single-photon counting module is one of the most widely used single-photon detectors. Due to its high detection efficiency and low dark counts in the visible and near-infrared region, it is reasonably chosen for basic research on quantum mechanics. Many researches have demonstrated that the maximum value of second-order photon correlation g(2)(τ) at zero delay (τ = 0) can be used to distinguish different light fields. Therefore, the HBT scheme containing two single photon detectors have been widely used in many advanced studies, such as space interference, ghost imaging, single photon detection with high efficiency, etc. However, higher-order photon correlations g(n) (n > 2) can reveal more measurable characteristics of light fields, such as information about the non-Gaussian scattering process, the skewness and kurtosis of photon number distribution, etc. When the extended HBT scheme is used to measure higher-order photon correlations, the experimental conditions including quantum efficiency and background noise greatly affect the photon correlation measurement. The influences of the counting rate and resolution time of the detection system on the measurements are also very important and cannot be ignored. Therefore, the comprehensive considering of various influence factors is necessary for accurately measuring the high-order photon correlations and also a challenge. In this paper, we present a method based on double Hanbury Brown-Twiss scheme for the accurate measuring of high-order photon correlations g(n) (n > 2). The system consists of four single photon counting modules and is used to detect and analyze the joint distribution probability of temporal photon correlation. Considering the effects of the background noise and overall efficiency, theoretically, we analyze the correlations of the third- and fourth-order photon with the incident light intensity, squeezing parameter and photon number respectively for thermal state, coherent state, squeezed vacuum state, and Fock state. Meanwhile, experimentally we study the influences of resolution time and counting rate on correlations of the coherent state and thermal state with third- and fourth-order photon. On condition that the resolution time is 210 ns and the counting rate is 80 kc/s, the correlations of third and fourth-order photon with the thermal state at zero time delay are accurately measured, and the relative statistical deviations of the measured vales from the theoretical values are 0.3% and 0.8%, respectively. In addition, the third- and fourth-order photon correlations of the thermal state at different delay times are also observed. It is demonstrated that the high-order photon correlations of light fields are measured accurately by comprehensively analyzing various influencing factors. This technique provides a promising and useful tool to investigate quantum correlated imaging and quantum coherence of light fields.

Acta Physica Sinica•Jan 1, 2020•3 citations

Qualification and Simulation of a Single Photon Source

Máté Galambos, Petra Seres, Eszter Udvary

Single-photon sources are key components of a quantum communication network; however, present-day realizations of such photon sources do not yet show an ideal behavior. A quantitative way to qualify them is by calculating the second order correlation function, as done in the Hanbury Brown-Twiss (HBT) experiment [1]. In this study a Bell-source that produces an entangled Bell sate was used as a single-photon source. When one branch is used as heralding for the other the source produces sub-Poisson photon statistics. This is not true for the non-heralded case. While conducting the HBT experiment in the non-heralded case we came across a phenomenon of double coincidence peaks. Through our study we found that this could be a result of two very distinct phenomenon, one of which is due to the non-ideal behavior of a single-photon source, the other due to secondary photons generated by single-photon avalanche diodes (SPADs). Both an ideal sub-Poisson statistic and the double coincidence peaks result in g(2)(0) = 0 by the HBT experiment, but in the first case the photon source is indeed an actual single-photon source, while in the second case this could also happen with a non-ideal single-photon source. For that reason, sometimes it is not sufficient to rely only on the HBT experiment to qualify a single-photon source, but also conduct some deeper experiments.

International Conference on Transparent Optical Networks•Jul 6, 2025•0 citations

Effects of counting rate and resolution time on a measurement of the intensity correlation function

Y. Li, Geng-Yuan Li, Y. C. Zhang +4 more

Non-photon-number-resolving single-photon-counting modules (SPCM's), also called on-off photon detectors, have been used in quantum optics for investigating the properties of various light fields based on the Hanbury-Brown-Twiss (HBT) experiment. However, for different incident light fields the experimental conditions can affect the measured photon statistics. In this paper, the second-order degree of coherence ${g}^{(2)}$, known as the important factor for quantitying a single-photon source, is experimentally investigated by means of the HBT scheme consisting of two SPCM's. By comparing the results of coherent field with that of the thermal field, we show that the measured ${g}^{(2)}$ is affected by the photon-counting rate and the resolution time from pulsed to continuous wave fields. The proper counting rate and resolution time for characterizing the exact photon statistical properties of input fields are determined.

Physical Review A•Jul 25, 2007•18 citations

Quantum correlations measured with multi-pixel detectors

Frauke Izdebski

use of any of the information contained in it must acknowledge this thesis as the source of the quotation or information. This thesis investigates the measurement of spatial correlations of photon pairs gener-ated through spontaneous parametric down-conversion with single-photon sensitive multi-pixel detectors. A custom designed and fabricated 8×1 fibre array detector for time to position multi-plexing was characterised. This detector was then commissioned in an experiment measuring the spatial correlations of photon pairs in position, momentum and in-termediate bases. The fibre array measured eight positions simultaneously with one Single-Photon Avalanche Diode, which led to an eight-fold increase in the data ac-quisition rate compared to traditional experiments, where a single SPAD was scanned across the detection plane. To capture all of the emitted light, an electron-multiplying CCD (EMCCD) camera was used. The spatial correlations were measured for the first time in momentum and pos-

•Aug 1, 2013•0 citations
It is not widely appreciated that many subtleties are involved in the accurate measurement of intensity-correlated photons; even for the original experiments of Hanbury Brown and Twiss (HBT). Using a monolithic 4 x 4 array of single-photon avalanche diodes (SPADs), together with an off-chip algorithm for processing streaming data, we investigate the difficulties of measuring second-order photon correlations g((2))(x(iota), t(iota),x, t) in a wide variety of light fields that exhibit dramatically different correlation statistics: a multimode He-Ne laser, an incoherent intensity-modulated lamp-light source and a thermal light source. Our off-chip algorithm treats multiple photon-arrivals at pixel-array pairs, in any observation interval, with photon fluxes limited by detector saturation, in such a way that a correctly normalized g((2)) function is guaranteed. The impact of detector background correlations between SPAD pixels and afterpulsing effects on second-order coherence measurements is discussed. These results demonstrate that our monolithic SPAD array enables access to effects that are otherwise impossible to measure with stand-alone detectors.
It is well known that totally incoherent light cannot exhibit first-order with photons that are uncorrelated, i.e., the normalized first-order correlation function is g(1)(0) = 0, whereas the second-order correlation function is g(2)(0) = 1. Less familiar is the fact that both chaotic and coherent sources can exhibit first-order interference, so that merely using the term interference is ambiguous. If fact, some previous QIQC presentations have centered around whether or not two-photon correlations are actually a form of two-photon interference.1 Another area of ambiguity concerns the detection of quantum state coherence using interference.2 In an attempt to disambiguate the concept of interference, we examine associated photon states using chaotic sources and the Hanbury Brown and Twiss (HBT) detection of bunched photons. The unambiguous determination of coherent quantum states has important applications for: (1) Atomic Bose-Einstein condensate (BEC) determined using scattered laser interference3 (2) Exciton-Polariton BEC determined using emitted photon interference4 (3) Coherent light states. (4) Characterizing photon statistics. (5) Characterization of extended sources. In this paper, we present imaging results for topics 3-5. The difficulties of HBT data acquisition are generally underappreciated. An advantage of our approach is super-linear speedup through the development of a new imaging device consisting of a 2-dimensional array of single-photon avalanche detectors.5, 6 A 4 × 4 array enables 120 HBT coincidence experiments to be run in parallel to generate the 2-dimensional distribution of g(2)(x) spatial correlations, thus making plausible the term g2 camera for this quantum imaging device.
Two-photon correlation measurement provides a promising way to experimentally demonstrate the statistical nature of a light source, which is very significant for the deep understanding of the photon-generating process and the diagnosing of the coherence property. Quantitatively two- photon correlation is described by second-order coherence. Usually the behavior of the second-order coherence against any of the parameters defining the phase volume is different for different photon statistics. The Poisson photon statistics for coherent light gives its second-order coherence as a flat response; The Bose-Einstein photon statistics for chaotic light gives its second-order coherence as a bunching effect; While the Sub-Poisson photon statistics for non-classical light gives its second-order coherence as an anti-bunching effect. Therefore the measurement of two-photon correlation is proved to be a good finger print to check whether light is in coherent state or incoherent state such as thermal state or non-classical state. Historically the measurement of two-photon correlation was first performed by Hanbury-Brown and Twiss (HBT) in 1956. They used a linear mixer to realize the correlation of the two currents from the photoelectric detectors illuminated by a stationary thermal light souece, a mercury arc, and the photo-bunching effect was first successfully observed in the visible region of 435.8 nm. HBT method is no doubt a good way to extract the small excess two-photon correlation for a stationary light because the background, that is the DC components, has been cut off automatically by the broad band amplifiers, which is in fact the key of the success of HBT experiment. However there exists a general problem, to which no attention has ever been paid, in measuring the two-photon correlation of non-stationary light such as synchrotron radiation (SR) by the HBT method. Here the "non-stationary" means a sense of classical mechanics that the observed intensity has some deterministic time structure. The systematic time structure of SR decided by the bunch distribution of the electric current in a storage ring will give rise to a large amount of unexpected accidental correlation, which in fact has nothing to do with the inherent photon statistics of light source and usually l000~l0000 times larger than the true two-photon correlation due to the short bunch separation length (2ns) and the short coherence time (~0.1ps) which is not comparable to the time resolution (1ns) of the measuring system. The existence of the accidental correlation would severely prevent us from observing the bunching effect of the true two-photon correlation. Therefore to suppress the much larger accidental correlation and to extract the small true two-photon correlation, a novel intensity interferometer has been developed for soft X-ray synchrotron radiation. This intensity interferometer consists of an optical vacuum chamber and an electric correlator. All the essential optical elements which includes a wire scanner, a precise diffraction slit, a grating monochromator with a coherence time modulator, a beam divider and two fast-response photon detectors (microchannel plates) are mounted in this high vacuum chamber. The electric correlator completes the multiplication of the two broad band electric currents coming from the photoelectric detectors. The basic idea to suppress the much larger accidental correlation is to modulate the coherence time by modulating the entrance slit width of the monochromator by a piezoclectric translator. The two sets of light intensity are simultaneously modulated too. When the frequency of modulation is f, the third harmonics 3f is detected with a loch-in amplifier because the 3f components include only the true two-photon correlation. Practically it is difficult to modulate with frequency f without any higher order harmonics distortion which might add some false 3f components. To overcome this difficulty we have used a sharp bandpass filter of l00~350 MHz in each branch of the correlator, which is lower than the RF frequency 500 MHz and much higher than 1.6 MHz, the revolution frequency of the stored beam of the 2.5 GeV storage ring. This new apparatus has been operated successfully in the measurement of the horizontal two-photon correlation for the first harmonic of undulator radiation with photon energy of 70 eV at the Photon Factory, KEK. By narrowing the precise slit width which correspondingly changes the spatial coherence of the incident SR, a bunching effect of the normalized excess two-photon correlation has been clearly observed. This explicit bunching effect implies that synchrotron radiation is chaotic radiation. Further investigation shows that although second-order coherence is completely determined by the first-order coherence for the case of chaotic light, the measured information from the light source is essentially different. The two-photon correlation of synchrotron radiation does not depend on the response time of the detectors but gives the information of instantaneous emittance of the stored beam with the time scale of coherence time τC. By fitting the experimental data, the horizontal instantaneous emittance of the stored beam is estimated to be 40nmrad. This intensity interferometer can be utilized to characterize the coherence properties of incomplete FELs, such as SASE, because if they are fully coherent light sources the normalized excess two-photon correlation would have a flat response, but not showing a photon-bunching effect.
High-order photon correlations of light fields are important for characterizing the quantum nature. Since Hanbury Brown and Twiss conducted the pioneering experiments in the 1950s, the HBT effect has inspired extensive research on high-order photon correlation in quantum optics, quantum information, and quantum imaging. The Single-photon counting module is one of the most widely used single-photon detectors. Due to its high detection efficiency and low dark counts in the visible and near-infrared region, it is reasonably chosen for basic research on quantum mechanics. Many researches have demonstrated that the maximum value of second-order photon correlation g(2)(τ) at zero delay (τ = 0) can be used to distinguish different light fields. Therefore, the HBT scheme containing two single photon detectors have been widely used in many advanced studies, such as space interference, ghost imaging, single photon detection with high efficiency, etc. However, higher-order photon correlations g(n) (n > 2) can reveal more measurable characteristics of light fields, such as information about the non-Gaussian scattering process, the skewness and kurtosis of photon number distribution, etc. When the extended HBT scheme is used to measure higher-order photon correlations, the experimental conditions including quantum efficiency and background noise greatly affect the photon correlation measurement. The influences of the counting rate and resolution time of the detection system on the measurements are also very important and cannot be ignored. Therefore, the comprehensive considering of various influence factors is necessary for accurately measuring the high-order photon correlations and also a challenge. In this paper, we present a method based on double Hanbury Brown-Twiss scheme for the accurate measuring of high-order photon correlations g(n) (n > 2). The system consists of four single photon counting modules and is used to detect and analyze the joint distribution probability of temporal photon correlation. Considering the effects of the background noise and overall efficiency, theoretically, we analyze the correlations of the third- and fourth-order photon with the incident light intensity, squeezing parameter and photon number respectively for thermal state, coherent state, squeezed vacuum state, and Fock state. Meanwhile, experimentally we study the influences of resolution time and counting rate on correlations of the coherent state and thermal state with third- and fourth-order photon. On condition that the resolution time is 210 ns and the counting rate is 80 kc/s, the correlations of third and fourth-order photon with the thermal state at zero time delay are accurately measured, and the relative statistical deviations of the measured vales from the theoretical values are 0.3% and 0.8%, respectively. In addition, the third- and fourth-order photon correlations of the thermal state at different delay times are also observed. It is demonstrated that the high-order photon correlations of light fields are measured accurately by comprehensively analyzing various influencing factors. This technique provides a promising and useful tool to investigate quantum correlated imaging and quantum coherence of light fields.
Single-photon sources are key components of a quantum communication network; however, present-day realizations of such photon sources do not yet show an ideal behavior. A quantitative way to qualify them is by calculating the second order correlation function, as done in the Hanbury Brown-Twiss (HBT) experiment [1]. In this study a Bell-source that produces an entangled Bell sate was used as a single-photon source. When one branch is used as heralding for the other the source produces sub-Poisson photon statistics. This is not true for the non-heralded case. While conducting the HBT experiment in the non-heralded case we came across a phenomenon of double coincidence peaks. Through our study we found that this could be a result of two very distinct phenomenon, one of which is due to the non-ideal behavior of a single-photon source, the other due to secondary photons generated by single-photon avalanche diodes (SPADs). Both an ideal sub-Poisson statistic and the double coincidence peaks result in g(2)(0) = 0 by the HBT experiment, but in the first case the photon source is indeed an actual single-photon source, while in the second case this could also happen with a non-ideal single-photon source. For that reason, sometimes it is not sufficient to rely only on the HBT experiment to qualify a single-photon source, but also conduct some deeper experiments.
Non-photon-number-resolving single-photon-counting modules (SPCM's), also called on-off photon detectors, have been used in quantum optics for investigating the properties of various light fields based on the Hanbury-Brown-Twiss (HBT) experiment. However, for different incident light fields the experimental conditions can affect the measured photon statistics. In this paper, the second-order degree of coherence g(2){g}^{(2)}g(2), known as the important factor for quantitying a single-photon source, is experimentally investigated by means of the HBT scheme consisting of two SPCM's. By comparing the results of coherent field with that of the thermal field, we show that the measured g(2){g}^{(2)}g(2) is affected by the photon-counting rate and the resolution time from pulsed to continuous wave fields. The proper counting rate and resolution time for characterizing the exact photon statistical properties of input fields are determined.
use of any of the information contained in it must acknowledge this thesis as the source of the quotation or information. This thesis investigates the measurement of spatial correlations of photon pairs gener-ated through spontaneous parametric down-conversion with single-photon sensitive multi-pixel detectors. A custom designed and fabricated 8×1 fibre array detector for time to position multi-plexing was characterised. This detector was then commissioned in an experiment measuring the spatial correlations of photon pairs in position, momentum and in-termediate bases. The fibre array measured eight positions simultaneously with one Single-Photon Avalanche Diode, which led to an eight-fold increase in the data ac-quisition rate compared to traditional experiments, where a single SPAD was scanned across the detection plane. To capture all of the emitted light, an electron-multiplying CCD (EMCCD) camera was used. The spatial correlations were measured for the first time in momentum and pos-