Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:0812.2485 · Physical Review Letters

Two-Qubit State Tomography Using a Joint Dispersive Readout

Stefan Filipp, Patrick Maurer, Peter Leek, Matthias Baur, R. Bianchetti, J. M. Fink, M. Göppl, L. Steffen, Jay Gambetta, Alexandre Blais, Andreas J. Wallraff

Published May 22, 2009• 175 citations
arXivHTMLPDF

Abstract

Quantum state tomography is an important tool in quantum information science for complete characterization of multiqubit states and their correlations. Here we report a method to perform a joint simultaneous readout of two superconducting qubits dispersively coupled to the same mode of a microwave transmission line resonator. The nonlinear dependence of the resonator transmission on the qubit state dependent cavity frequency allows us to extract the full two-qubit correlations without the need for single-shot readout of individual qubits. We employ standard tomographic techniques to reconstruct the density matrix of two-qubit quantum states.

DOI
10.1103/physrevlett.102.200402

Related papers

Dynamics of dispersive single-qubit readout in circuit quantum electrodynamics

R. Bianchetti, Stefan Filipp, Matthias Baur +6 more

The quantum state of a superconducting qubit nonresonantly coupled to a transmission line resonator can be determined by measuring the quadrature amplitudes of an electromagnetic field transmitted through the resonator. We present experiments in which we analyze in detail the dynamics of the transmitted field as a function of the measurement frequency for both weak continuous and pulsed measurements. We find excellent agreement between our data and calculations based on a set of Bloch-type differential equations for the cavity field derived from the dispersive Jaynes-Cummings Hamiltonian including dissipation. We show that the measured system response can be used to construct a measurement operator from which the qubit population can be inferred accurately. Such a measurement operator can be used in tomographic methods to reconstruct single and multiqubit states in ensemble-averaged measurements.

arXiv:0907.2549•Physical Review A•Oct 30, 2009•78 citations

Catch-Disperse-Release Readout for Superconducting Qubits

Eyob Alebachew Sete, Andrei Galiautdinov, Eric Mlinar +2 more

We analyze a single-shot readout for superconducting qubits via the controlled catch, dispersion, and release of a microwave field. A tunable coupler is used to decouple the microwave resonator from the transmission line during the dispersive qubit-resonator interaction, thus circumventing damping from the Purcell effect. We show that, if the qubit frequency tuning is sufficiently adiabatic, a fast high-fidelity qubit readout is possible, even in the strongly nonlinear dispersive regime. Interestingly, the Jaynes-Cummings nonlinearity leads to the quadrature squeezing of the resonator field below the standard quantum limit, resulting in a significant decrease of the measurement error.

arXiv:1302.7020•Physical Review Letters•May 22, 2013•31 citations

Benchmarking a Quantum Teleportation Protocol in Superconducting Circuits Using Tomography and an Entanglement Witness

Matthias Baur, Arkady Fedorov, L. Steffen +3 more

Teleportation of a quantum state may be used for distributing entanglement between distant qubits in quantum communication and for quantum computation. Here we demonstrate the implementation of a teleportation protocol, up to the single-shot measurement step, with superconducting qubits coupled to a microwave resonator. Using full quantum state tomography and evaluating an entanglement witness, we show that the protocol generates a genuine tripartite entangled state of all three qubits. Calculating the projection of the measured density matrix onto the basis states of two qubits allows us to reconstruct the teleported state. Repeating this procedure for a complete set of input states we find an average output state fidelity of 86%.

arXiv:1107.4774•Physical Review Letters•Jan 24, 2012•88 citations

Entanglement Metrology Using a Joint Readout of Superconducting Qubits

Jerry M. Chow, L. DiCarlo, Jay Gambetta +6 more

Accurate and precise detection of multi-qubit entanglement is key for the experimental development of quantum computation. Traditionally, non-classical correlations between entangled qubits are measured by counting coincidences between single-shot readouts of individual qubits. We report entanglement metrology using a single detection channel with direct access to ensemble-averaged correlations between two superconducting qubits. Following validation and calibration of this joint readout, we demonstrate full quantum tomography on both separable and highly-entangled two-qubit states produced on demand. Using a subset of the measurements required for full tomography, we perform entanglement metrology with ~95% accuracy and ~98% precision despite ~10% fidelity of single measurements. For the highly entangled states, measured Clauser-Horne-Shimony-Holt operators reach a maximum value of 2.61+/-0.04 and entanglement witnesses give a lower bound of ~88% on concurrence. In its present form, this detector will be able to resolve future improvements in the production of two-qubit entanglement and is immediately extendable to 3 or 4 qubits.

arXiv:0908.1955•Aug 13, 2009•10 citations

Using sideband transitions for two-qubit operations in superconducting circuits

Peter Leek, Stefan Filipp, Patrick Maurer +6 more

We demonstrate the time-resolved driving of two-photon blue sideband transitions between superconducting qubits and a transmission line resonator. As an example of using these sideband transitions for a two-qubit operation, we implement a pulse sequence that first entangles one qubit with the resonator and subsequently distributes the entanglement between two qubits. We show the generation of 75% fidelity Bell states by this method. The full density matrix of the two-qubit system is extracted using joint measurement and quantum state tomography and shows close agreement with numerical simulation.

arXiv:0812.2678•Physical Review B•May 29, 2009•224 citations

Readout error mitigated quantum state tomography tested on superconducting qubits

Adrian Skasberg Aasen, Andras Di Giovanni, Hannes Rotzinger +2 more

Abstract Quantum technologies rely heavily on accurate control and reliable readout of quantum systems. Current experiments are limited by numerous sources of noise that can only be partially captured by simple analytical models and additional characterization of the noise sources is required. We test the ability of readout error mitigation to correct noise found in systems composed of quantum two-level objects (qubits). To probe the limit of such methods, we designed a beyond-classical readout error mitigation protocol based on quantum state tomography (QST), which estimates the density matrix of a quantum system, and quantum detector tomography (QDT), which characterizes the measurement procedure. By treating readout error mitigation in the context of state tomography the method becomes largely readout mode-, architecture-, noise source-, and quantum state-independent. We implement this method on a superconducting qubit and evaluate the increase in reconstruction fidelity for QST. We characterize the performance of the method by varying important noise sources, such as suboptimal readout signal amplification, insufficient resonator photon population, off-resonant qubit drive, and effectively shortened T1 and T2 coherence. As a result, we identified noise sources for which readout error mitigation worked well, and observed decreases in readout infidelity by a factor of up to 30.

arXiv:2312.04211•Communications Physics•Sep 6, 2024•15 citations
Quantum state tomography is an important tool in quantum information science for complete characterization of multiqubit states and their correlations. Here we report a method to perform a joint simultaneous readout of two superconducting qubits dispersively coupled to the same mode of a microwave transmission line resonator. The nonlinear dependence of the resonator transmission on the qubit state dependent cavity frequency allows us to extract the full two-qubit correlations without the need for single-shot readout of individual qubits. We employ standard tomographic techniques to reconstruct the density matrix of two-qubit quantum states.
The quantum state of a superconducting qubit nonresonantly coupled to a transmission line resonator can be determined by measuring the quadrature amplitudes of an electromagnetic field transmitted through the resonator. We present experiments in which we analyze in detail the dynamics of the transmitted field as a function of the measurement frequency for both weak continuous and pulsed measurements. We find excellent agreement between our data and calculations based on a set of Bloch-type differential equations for the cavity field derived from the dispersive Jaynes-Cummings Hamiltonian including dissipation. We show that the measured system response can be used to construct a measurement operator from which the qubit population can be inferred accurately. Such a measurement operator can be used in tomographic methods to reconstruct single and multiqubit states in ensemble-averaged measurements.
We analyze a single-shot readout for superconducting qubits via the controlled catch, dispersion, and release of a microwave field. A tunable coupler is used to decouple the microwave resonator from the transmission line during the dispersive qubit-resonator interaction, thus circumventing damping from the Purcell effect. We show that, if the qubit frequency tuning is sufficiently adiabatic, a fast high-fidelity qubit readout is possible, even in the strongly nonlinear dispersive regime. Interestingly, the Jaynes-Cummings nonlinearity leads to the quadrature squeezing of the resonator field below the standard quantum limit, resulting in a significant decrease of the measurement error.
Teleportation of a quantum state may be used for distributing entanglement between distant qubits in quantum communication and for quantum computation. Here we demonstrate the implementation of a teleportation protocol, up to the single-shot measurement step, with superconducting qubits coupled to a microwave resonator. Using full quantum state tomography and evaluating an entanglement witness, we show that the protocol generates a genuine tripartite entangled state of all three qubits. Calculating the projection of the measured density matrix onto the basis states of two qubits allows us to reconstruct the teleported state. Repeating this procedure for a complete set of input states we find an average output state fidelity of 86%.
Accurate and precise detection of multi-qubit entanglement is key for the experimental development of quantum computation. Traditionally, non-classical correlations between entangled qubits are measured by counting coincidences between single-shot readouts of individual qubits. We report entanglement metrology using a single detection channel with direct access to ensemble-averaged correlations between two superconducting qubits. Following validation and calibration of this joint readout, we demonstrate full quantum tomography on both separable and highly-entangled two-qubit states produced on demand. Using a subset of the measurements required for full tomography, we perform entanglement metrology with ~95% accuracy and ~98% precision despite ~10% fidelity of single measurements. For the highly entangled states, measured Clauser-Horne-Shimony-Holt operators reach a maximum value of 2.61+/-0.04 and entanglement witnesses give a lower bound of ~88% on concurrence. In its present form, this detector will be able to resolve future improvements in the production of two-qubit entanglement and is immediately extendable to 3 or 4 qubits.
We demonstrate the time-resolved driving of two-photon blue sideband transitions between superconducting qubits and a transmission line resonator. As an example of using these sideband transitions for a two-qubit operation, we implement a pulse sequence that first entangles one qubit with the resonator and subsequently distributes the entanglement between two qubits. We show the generation of 75% fidelity Bell states by this method. The full density matrix of the two-qubit system is extracted using joint measurement and quantum state tomography and shows close agreement with numerical simulation.
Abstract Quantum technologies rely heavily on accurate control and reliable readout of quantum systems. Current experiments are limited by numerous sources of noise that can only be partially captured by simple analytical models and additional characterization of the noise sources is required. We test the ability of readout error mitigation to correct noise found in systems composed of quantum two-level objects (qubits). To probe the limit of such methods, we designed a beyond-classical readout error mitigation protocol based on quantum state tomography (QST), which estimates the density matrix of a quantum system, and quantum detector tomography (QDT), which characterizes the measurement procedure. By treating readout error mitigation in the context of state tomography the method becomes largely readout mode-, architecture-, noise source-, and quantum state-independent. We implement this method on a superconducting qubit and evaluate the increase in reconstruction fidelity for QST. We characterize the performance of the method by varying important noise sources, such as suboptimal readout signal amplification, insufficient resonator photon population, off-resonant qubit drive, and effectively shortened T1 and T2 coherence. As a result, we identified noise sources for which readout error mitigation worked well, and observed decreases in readout infidelity by a factor of up to 30.