Optimizing capture efficiency in a magneto-optical trap
Michelle S. Stephens, Carl Wieman, Kristan L. Corwin +3 more
We have studied the user of vapor-cell magneto-optical traps for the collection and investigation of trace elements of radioactive isotopes. The fundamental processes governing efficient collection of neutral isotopes in a trap have been identified and integrated into a model that accurately describes the collection process. The model has been verified experimentally; a 6% capture efficiency has been demonstrated for stable Cs isotopes and we predict a simple change in trapping cell geometry will allow a 50% capture efficiency. This paper discussed the issues involved in efficient capture, such as the trapping laser properties and wall-coatings. It describes a new cell design for efficient capture and discusses current work towards trapping small numbers of 221Fr (T1/2 equals 4.8 minutes) atoms.© (1995) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 7, 1995•0 citations