We present a cooling mechanism for a nanomechanical resonator that linearly couples with a LC oscillator. The linear coupling, when periodically modulated at red detuning, up-converts the low-frequency nanomechanical quanta to the high-frequency LC oscillator quanta which then dissipates in the circuits via the damping of the LC oscillator. We show that realistic circuit can be designed in the superconducting system to implement this scheme in the resolved-sideband regime and reach the quantum ground state of the nanomechanical mode. A detailed study of the origin of the quantum back-action noise in this cooling process is also presented.
We present a cooling mechanism for a nanomechanical resonator that linearly couples with a LC oscillator. The linear coupling, when periodically modulated at red detuning, up-converts the low-frequency nanomechanical quanta to the high-frequency LC oscillator quanta which then dissipates in the circuits via the damping of the LC oscillator. We show that realistic circuit can be designed in the superconducting system to implement this scheme in the resolved-sideband regime and reach the quantum ground state of the nanomechanical mode. A detailed study of the origin of the quantum back-action noise in this cooling process is also presented.
The coupled dynamics of a nanomechanical resonator and superconducting quantum circuits are studied in three experiments, in the context of studying the quantum limit for force detection and quantum physics of macroscopic objects. In the first experiment, the dispersive mechanical resonance shift from the interaction with a Cooper-pair box qubit is studied. The measured coupling strength is large enough to satisfy one of the conditions required to perform many of the proposed quantum nanomechanical measurements. The resonance shift also probes the microwave-driven response of the qubit, showing Rabi oscillation and Landau-Zener tunneling, proving the coherent dynamics of the qubit. Second, the parametric excitation of nanomechanical motion is studied via experiments with a driven qubit. Degenerate parametric amplification and oscillation are demonstrated, with a new observation of nonlinear dissipation. The squeezing of the back-action noise from the detection amplifier is also observed, up to 4dB. It is the first demonstration using a qubit as an auxiliary system to modify the nanomechanical dynamics, showing a possible route for generation of nanomechanical quantum states. Finally, back-action cooling of nanomechanical motion has been investigated, which is implemented by capacitively coupling a high-Q coplanar waveguide microwave resonator to a nanomechanical resonator. The thermal state with 7.5 mechanical quanta on average is reached, a result that is ultimately limited due to increased bath heating with microwave power. The heating is consistent with a model based on two-level systems resonantly coupled to the nanomechanical mode. This additional heating suggests future efforts to improve coupling and for reducing two-level system density in materials employed to reach the motional ground state via back-action cooling.
We present a complete theory for laser cooling of a macroscopic radio-frequency LC electrical circuit by means of an optoelectromechanical system, consisting of an optical cavity dispersively coupled to a nanomechanical oscillator, which is in turn capacitively coupled to the LC circuit of interest. We determine the optimal parameter regime where the LC resonator can be cooled down to its quantum ground state, which requires a large optomechanical cooperativity, and a larger electromechanical cooperativity. Moreover, comparable optomechanical and electromechanical coupling rates are preferable for reaching the quantum ground state.
Abstract. In this paper we present a scheme for ground state cooling of a flexural mode of a nanomechanical beam incorporated in a loop-shaped Cooper-pair box (CPB) circuit. Via the Lorentz force coupling of the beam motion to circulating CPB-circuit currents, energy is transferred to the CPB qubit which acts as a dissipative two-level system. The cooling process is driven by a detuned gate-voltage drive acting on the CPB. We analyze the cooling force spectrum and present analytical expressions for the cooling rate and final occupation number for a wide parameter regime. In particular, we find that cooling is optimized in a strong drive regime, and we present the necessary conditions for ground-state cooling. PACS numbers: 85.25.-j, 85.85.+j, 37.10.RsGround state cooling of a nanomechanical resonator via a Cooper pair box qubit 2
We present a scheme for ground-state cooling of a mechanical resonator by simultaneously coupling it to a superconducting qubit and a cavity field. The Hamiltonian describing the hybrid system dynamics is systematically derived. The cooling process is driven by a red-detuned ac drive on the qubit and a laser drive on the optomechanical cavity. We have investigated cooling in the weak and the strong coupling regimes for both the individual system, i.e., qubit assisted cooling and optomechanical cooling, and compared them with the effective hybrid cooling. We show that in the weak coupling and resolved sideband regime, cooling is more efficient in the hybrid case for a specific choice of parameters. On the other hand, in the strong coupling, the hybrid cooling is found to be more effective compared to the individual cooling mechanisms in the resolved regimes.
The application of quantum mechanics to macroscopic motion suggests many counterintuitive phenomena. While the quantum nature of the motion of individual atoms and molecules has long been successfully studied, an equivalent demonstration of the motion of a near-macroscopic structure remains a challenge in experimental physics. A nanomechanical resonator is an excellent system for such a study. It typically contains > 10 10 atoms, and it may be modeled in terms of macroscopic parameters such as bulk density and elasticity. Yet it behaves like a simple harmonic oscillator, with mass low enough and resonant frequency high enough for its quantum zero-point motion and single energy quanta to be experimentally accessible. In pursuit of quantum phenomena in a mechanical oscillator, two important goals are to prepare the oscillator in its quantum ground state, and to measure its position with a precision limited by the Heisenberg uncertainty principle. In this work we have demonstrated techniques that advance towards both of these goals. Our system comprises a 30 micron × 170 nm, 2.2 pg, 5.57 MHz nanomechanical resonator capacitively coupled to a 5 GHz superconducting microwave resonator. The microwave resonator and nanomechanical resonator are fabricated together onto a single silicon chip and measured in a dilution refrigerator at temperatures below 150 mK. At these temperatures the coupling of the motion to the thermal environment is very small, resulting in a very high mechanical Q, approaching ∼ 10 6 . By driving with a microwave pump signal, we observed sidebands generated by the mechanical motion and used these to measure the thermal motion of the resonator. Applying a pump tone red-detuned from the microwave resonance, we used the microwave field to damp the mechanical resonator, extracting energy and "cooling" the motion in a manner similar to optical cooling of trapped atoms. Starting from a mode temperature of ∼ 150 mK, we reached ∼ 40 mK by this "backaction cooling" technique, corresponding to an occupation factor only ∼ 150 times above the ground state of motion. We also determined the precision of our device in measurement of position. Quantum mechanics dictates that, in a continuous position measurement, the precision may be no better than the zero-point motion of the resonator. Increasing the coupling of the resonator to detector will eventually result in back-action driving of the motion, adding imprecision and enforcing this limit. We demonstrated that our system is capable of precisions approaching this limit, and identified the primary experimental factors preventing us from reaching it: noise added to the measurement by our amplifier, and excess dissipation appearing in our microwave resonator at high pump powers. Furthermore, by applying both red- and blue-detuned phase-coherent microwave pump signals, we demonstrated back-action evading (BAE) measurement sensitive to only a single quadrature of the motion. By avoiding the back-action driving in the measured quadrature, such a technique has the potential for precisions surpassing the limit of the zero-point motion. With this method, we achieved a measurement precision of ∼ 100 fm, or 4 times the quantum zero-point motion of the mechanical resonator. We found that the measured quadrature is insensitive to back-action driving by at least a factor of 82 relative to the unmeasured quadrature. We also identified a mechanical parametric amplification effect which arises during the BAE measurement. This effect sets limits on the BAE performance but also mechanically preamplifies the motion, resulting in a position resolution 1.3 times the zero-point motion. We discuss how to overcome the experimental limits set by amplifier noise, pump power and parametric amplification. These results serve to define the path forward for demonstrating truly quantum-limited measurement and non-classical states of motion in a nearly-macroscopic object.
In this paper, we present a scheme for ground-state cooling of a flexural mode of a nanomechanical beam incorporated in a loop-shaped Cooper-pair box (CPB) circuit. Via the Lorentz force coupling of the beam motion to circulating CPB-circuit currents, energy is transferred to the CPB qubit which acts as a dissipative two-level system. The cooling process is driven by a detuned gate voltage drive acting on the CPB. We analyze the cooling force spectrum and present analytical expressions for the cooling rate and final occupation number for a wide parameter regime. In particular, we find that cooling is optimized in a strong drive regime, and we present the necessary conditions for ground-state cooling.