Quantum trajectory theory is the best mathematical set up to model continual observations of a quantum system and feedback based on the observed output. Inside this framework, we study how to enhance the squeezing of the fluorescence light emitted by a two-level atom, stimulated by a coherent monochromatic laser. In the presence of a Wiseman-Milburn feedback scheme, based on the homodyne detection of a fraction of the emitted light, we analyze the squeezing dependence on the various control parameters.
Quantum trajectory theory is the best mathematical set up to model continual observations of a quantum system and feedback based on the observed output. Inside this framework, we study how to enhance the squeezing of the fluorescence light emitted by a two-level atom, stimulated by a coherent monochromatic laser. In the presence of a Wiseman-Milburn feedback scheme, based on the homodyne detection of a fraction of the emitted light, we analyze the squeezing dependence on the various control parameters.
Among the formulations of the theory of quantum measurements in continuous time, quantum trajectory theory is very suitable for the introduction of measurement based feedback and closed loop control of quantum systems. In this paper we present such a construction in the concrete case of a two-level atom stimulated by a coherent, monochromatic laser. In particular, we show how fast feedback à la Wiseman and Milburn can be introduced in the formulation of the theory. Then, the spectrum of the free fluorescence light is studied and typical quantum phenomena, squeezing and sub-natural line-narrowing, are presented.
We consider a trapped two-level atom stimulated by a coherent monochromatic laser and we study how to enhance the squeezing of the fluorescence light in the presence of a Wiseman-Milburn feedback mechanism, based on the homodyne detection of a fraction of the emitted light. We analyze the effect of the control parameters on the properties of the spectrum of light and we also discuss the relation between light squeezing and atomic states, which qualitatively changes when the control is present. We also show that feedback can produce sub-natural line narrowing of the fluorescence light, without the presence of squeezing in the stimulating light. The whole problem is tackled inside the framework of the quantum trajectory theory.
In this article, we reconsider a version of quantum trajectory theory based on the stochastic Schrödinger equation with stochastic coefficients, which was mathematically introduced in the 1990s, and we develop it in order to describe the non-Markovian evolution of a quantum system continuously measured and controlled, thanks to a measurement-based feedback. Indeed, realistic descriptions of a feedback loop have to include delay and thus need a non-Markovian theory. The theory allows us to put together non-Markovian evolutions and measurements in continuous time, in agreement with the modern axiomatic formulation of quantum mechanics. To illustrate the possibilities of such a theory, we apply it to a two-level atom stimulated by a laser. We introduce closed loop control too, via the stimulating laser, with the aim of enhancing the 'squeezing' of the emitted light, or other typical quantum properties. Note that here we change the point of view with respect to the usual applications of control theory. In our model, the 'system' is the two-level atom, but we do not want to control its state, to bring the atom to a final target state. Our aim is to control the 'Mandel Q-parameter' and the spectrum of the emitted light; in particular, the spectrum is not a property at a single time, but involves a long interval of times (a Fourier transform of the autocorrelation function of the observed output is needed).
This thesis considers two types of applications of quantum feedback control; feedback creation of nonclassical states of light, and controlling nonclassical properties of an ensemble of atoms. An electro-optical feedback loop will create an in-loop field with nonclassical photon statistics similar to squeezed light, resulting in fluorescence line-narrowing of a two-level atom coupled to such light. We extend this theory to study a three-level atom coupled to broadband squashed light, and confirm the two-level atom line-narrowing using a more realistic non-Markovian description of the feedback loop. The second type of application utilizes continuous QND measurement of atomic ensembles. If we measure the collective spin, then the system experiences conditional spin squeezing dependent on the measurement results. We show that feedback based on these results can continuously drive the system into the same conditioned state, resulting in deterministically reproducible spin squeezing. If we measure the atom number fluctuations of a BEC, then, due to the nonlinearity of atomic self interactions, this is also information about phase fluctuations. We show that feedback based on this information can greatly reduce the collisional broadening of the linewidth of an atom laser out-coupled from the condensate.
We compare two different approaches to the control of the dynamics of a continuously monitored open quantum system. The first is Markovian feedback, as introduced in quantum optics by Wiseman and Milburn [Phys. Rev. Lett. 70, 548 (1993)]. The second is feedback based on an estimate of the system state, developed recently by Doherty and Jacobs [Phys. Rev. A 60, 2700 (1999)]. Here we choose to call it, for brevity, Bayesian feedback. For systems with nonlinear dynamics, we expect these two methods of feedback control to give markedly different results. The simplest possible nonlinear system is a driven and damped two-level atom, so we choose this as our model system. The monitoring is taken to be homodyne detection of the atomic fluorescence, and the control is by modulating the driving. The aim of the feedback in both cases is to stabilize the internal state of the atom as close as possible to an arbitrarily chosen pure state, in the presence of inefficient detection and other forms of decoherence. Our results (obtained without recourse to stochastic simulations) prove that Bayesian feedback is never inferior, and is usually superior, to Markovian feedback. However, it would be far more difficult to implement than Markovian feedback and it loses its superiority when obvious simplifying approximations are made. It is thus not clear which form of feedback would be better in the face of inevitable experimental imperfections.
We present the quantum theory of optical cavity feedback mediated by homodyne detection, with an arbitrary time delay. We apply this theory to a system with nonclassical dynamics, a sub-Poissonian pumped laser. By using the feedback to phase lock the laser it is possible to produce output light which exhibits perfect quadrature squeezing on resonance, rather than just sub-Poissonian intensity statistics. However, we also show that feedback mediated by homodyne detection (or any other extracavity measurement) cannot produce nonclassical light unless the cavity dynamics can do so without feedback. Furthermore, in systems which already exhibit squeezing, such feedback can only degrade the squeezing in the output. With feedback mediated by an intracavity measurement, these theorems do not apply. We show that an (admittedly unrealistic) intracavity quantum nondemolition quadrature measurement allows arbitrary squeezing to be produced by controlling the amplitude of a coherent driving field.