arXiv:0707.2930 · Optics Letters

Strong saturation absorption imaging of dense clouds of ultracold atoms

Gael Reinaudi, Thierry Lahaye, Z. Wang, David Guéry-Odelin

Published Oct 23, 2007• 231 citations
arXivHTMLPDF

Abstract

We report on a far above saturation absorption imaging technique to investigate the characteristics of dense packets of ultracold atoms. The transparency of the cloud is controlled by the incident light intensity as a result of the nonlinear response of the atoms to the probe beam. We detail our experimental procedure to calibrate the imaging system for reliable quantitative measurements and demonstrate the use of this technique to extract the profile and its spatial extent of an optically thick atomic cloud.

DOI
10.1364/ol.32.003143

Related papers

Calibration of saturation absorption imaging of ultracold atom clouds

Woo Jin Kwon, Jae-yoon Choi, Yong-il Shin

We describe an experimental method to calibrate an absorption imaging system for ultracold atom clouds. Optical density profiles of an atom cloud are obtained for various probe beam intensities and are analyzed to determine the correction factor for the effective probe beam intensity directly from saturation effects. We find that the temporal shape of the probe-beam pulse needs to be taken into account for a quantitative analysis of the optical density measured in saturation absorption imaging. We show that this pulse-shape effect can lead to distortion of the density profile due to its nonlinear dependence on the optical depth.

Journal of the Korean Physical Society•Dec 1, 2012•7 citations

Calibrating high intensity absorption imaging of ultracold atoms

Klaus Hueck, Niclas Luick, Lennart Sobirey +5 more

Absorption imaging of ultracold atoms is the foundation for quantitative extraction of information from experiments with ultracold atoms. Due to the limited exposure time available in these systems, the signal-to-noise ratio is largest for high intensity absorption imaging where the intensity of the imaging light is on the order of the saturation intensity. In this case, the absolute value of the intensity of the imaging light enters as an additional parameter making it more sensitive to systematic errors. Here, we present a novel and robust technique to determine the imaging beam intensity in units of the effective saturation intensity to better than 5%. We do this by measuring the momentum transferred to the atoms by the imaging light while varying its intensity. We further utilize the method to quantify the purity of the polarization of the imaging light and to determine the correct imaging detuning.

arXiv:1702.01943•Optics Express•Apr 4, 2017•49 citations

Spatial calibration of high-density absorption imaging

Toke Vibel, M B Christensen, M A Kristensen +4 more

Abstract The accurate determination of atom numbers is an ubiquitous problem in the field of ultracold atoms. For modest atom numbers, absolute calibration techniques are available, however, for large numbers and high densities, the available techniques neglect many-body scattering processes. Here, a spatial calibration technique for time-of-flight absorption images of ultracold atomic clouds is presented. The calibration is obtained from radially averaged absorption images and we provide a practical guide to the calibration process. It is shown that the calibration coefficient scales linearly with optical density and depends on the absorbed photon number for the experimental conditions explored here. This allows for the direct inclusion of a spatially dependent calibration in the image analysis. For typical ultracold atom clouds the spatial calibration technique leads to corrections in the detected atom number up to ≈ 12 % and temperature up to ≈ 14 % in comparison to previous calibration techniques. The technique presented here addresses a major difficulty in absorption imaging of ultracold atomic clouds and prompts further theoretical work to understand the scattering processes in ultracold dense clouds of atoms for accurate atom number calibration.

arXiv:2402.06514•Journal of Physics B Atomic Molecular and Optical Physics•Jun 3, 2024•7 citations

Illustration of Babinet's principle with ultracold atoms

Aaron Reinhard, Jean-Félix Riou, Laura A. Zundel +1 more

We demonstrate Babinet's principle by the absorption of high intensity light from dense clouds of ultracold atoms. Images of the diffracted light are directly related to the spatial distribution of atoms. The advantages of employing Babinet's principle as an imaging technique are that it is easy to implement and the detected signal is large. We discuss the regimes of applicability of this technique as well as its limitations.

arXiv:1310.6983•Oct 25, 2013•0 citations

Phase-contrast imaging of a dense atomic cloud

Marcia Frometa Fernandez, Pablo Gabriel Santos Dias, P. H. N. Magnani +5 more

We present the experimental production and characterization of a dense cold atomic cloud of \(^{88}\text{Sr}\) atoms, optimized for the future studies of light transport in highly dense regimes. Using narrow-line molasses on the 689 nm transition, combined with a far off-resonant optical dipole trap, we achieve spatial densities as high as \(7.9 \times 10^{13} \, \text{atoms/cm}^3\) and optical depths up to 64. This approach stands out from previous methods by integrating narrow-line molasses with an optical dipole trap, enabling high-density samples without relying on evaporative cooling. Unlike traditional absorption imaging, which becomes inaccurate in such dense regimes, we demonstrate that phase-contrast imaging (PCI) can reliably reconstruct the in-situ density profile even for highly spatially and optically dense samples. The use of a spatial light modulator instead of a fixed phase plate in the PCI setup provides enhanced flexibility and control of imaging parameters, making this imaging technique robust against imaging artifacts and adaptable to varying experimental conditions. Moreover, we derive theoretical conditions for reliable PCI operation in dense regimes and validate these experimentally, showing excellent agreement with time-of-flight measurements even at the highest densities. Our results establish a robust method for producing and characterizing dense atomic clouds.

arXiv:2501.03158•Jan 6, 2025•0 citations

Phase-contrast imaging of a dense atomic cloud

Marcia Frómeta Fernández, Pablo Gabriel Santos Dias, P. H. N. Magnani +5 more

We demonstrate that phase-contrast imaging (PCI) can reliably reconstruct the in situ density profile even for highly spatially and optically dense samples. In our experiment, we achieve high spatial densities of up to 7.9 × 1013 atoms/cm3 and optical depths up to 64 in a dense cold atomic cloud of 88Sr atoms. The use of a spatial light modulator instead of a fixed phase plate in the PCI setup provides enhanced flexibility and control of imaging parameters, making this imaging technique robust against imaging artifacts and adaptable to varying experimental conditions. Moreover, we quantify the conditions under which the standard single-atom polarizability model remains accurate for PCI in a density regime where collective effects should modify the atomic response of the system. We experimentally validate our statements by showing excellent agreement with time-of-flight measurements even at the highest densities. Our results establish PCI as a reliable and versatile method for characterizing spatially dense atomic clouds.

Review of Scientific Instruments•Aug 1, 2025•1 citation
We report on a far above saturation absorption imaging technique to investigate the characteristics of dense packets of ultracold atoms. The transparency of the cloud is controlled by the incident light intensity as a result of the nonlinear response of the atoms to the probe beam. We detail our experimental procedure to calibrate the imaging system for reliable quantitative measurements and demonstrate the use of this technique to extract the profile and its spatial extent of an optically thick atomic cloud.
We describe an experimental method to calibrate an absorption imaging system for ultracold atom clouds. Optical density profiles of an atom cloud are obtained for various probe beam intensities and are analyzed to determine the correction factor for the effective probe beam intensity directly from saturation effects. We find that the temporal shape of the probe-beam pulse needs to be taken into account for a quantitative analysis of the optical density measured in saturation absorption imaging. We show that this pulse-shape effect can lead to distortion of the density profile due to its nonlinear dependence on the optical depth.
Absorption imaging of ultracold atoms is the foundation for quantitative extraction of information from experiments with ultracold atoms. Due to the limited exposure time available in these systems, the signal-to-noise ratio is largest for high intensity absorption imaging where the intensity of the imaging light is on the order of the saturation intensity. In this case, the absolute value of the intensity of the imaging light enters as an additional parameter making it more sensitive to systematic errors. Here, we present a novel and robust technique to determine the imaging beam intensity in units of the effective saturation intensity to better than 5%. We do this by measuring the momentum transferred to the atoms by the imaging light while varying its intensity. We further utilize the method to quantify the purity of the polarization of the imaging light and to determine the correct imaging detuning.
Abstract The accurate determination of atom numbers is an ubiquitous problem in the field of ultracold atoms. For modest atom numbers, absolute calibration techniques are available, however, for large numbers and high densities, the available techniques neglect many-body scattering processes. Here, a spatial calibration technique for time-of-flight absorption images of ultracold atomic clouds is presented. The calibration is obtained from radially averaged absorption images and we provide a practical guide to the calibration process. It is shown that the calibration coefficient scales linearly with optical density and depends on the absorbed photon number for the experimental conditions explored here. This allows for the direct inclusion of a spatially dependent calibration in the image analysis. For typical ultracold atom clouds the spatial calibration technique leads to corrections in the detected atom number up to ≈ 12 % and temperature up to ≈ 14 % in comparison to previous calibration techniques. The technique presented here addresses a major difficulty in absorption imaging of ultracold atomic clouds and prompts further theoretical work to understand the scattering processes in ultracold dense clouds of atoms for accurate atom number calibration.
We present the experimental production and characterization of a dense cold atomic cloud of 88Sr^{88}\text{Sr}88Sr atoms, optimized for the future studies of light transport in highly dense regimes. Using narrow-line molasses on the 689 nm transition, combined with a far off-resonant optical dipole trap, we achieve spatial densities as high as 7.9×1013 atoms/cm37.9 \times 10^{13} \, \text{atoms/cm}^37.9×1013atoms/cm3 and optical depths up to 64. This approach stands out from previous methods by integrating narrow-line molasses with an optical dipole trap, enabling high-density samples without relying on evaporative cooling. Unlike traditional absorption imaging, which becomes inaccurate in such dense regimes, we demonstrate that phase-contrast imaging (PCI) can reliably reconstruct the in-situ density profile even for highly spatially and optically dense samples. The use of a spatial light modulator instead of a fixed phase plate in the PCI setup provides enhanced flexibility and control of imaging parameters, making this imaging technique robust against imaging artifacts and adaptable to varying experimental conditions. Moreover, we derive theoretical conditions for reliable PCI operation in dense regimes and validate these experimentally, showing excellent agreement with time-of-flight measurements even at the highest densities. Our results establish a robust method for producing and characterizing dense atomic clouds.
We demonstrate that phase-contrast imaging (PCI) can reliably reconstruct the in situ density profile even for highly spatially and optically dense samples. In our experiment, we achieve high spatial densities of up to 7.9 × 1013 atoms/cm3 and optical depths up to 64 in a dense cold atomic cloud of 88Sr atoms. The use of a spatial light modulator instead of a fixed phase plate in the PCI setup provides enhanced flexibility and control of imaging parameters, making this imaging technique robust against imaging artifacts and adaptable to varying experimental conditions. Moreover, we quantify the conditions under which the standard single-atom polarizability model remains accurate for PCI in a density regime where collective effects should modify the atomic response of the system. We experimentally validate our statements by showing excellent agreement with time-of-flight measurements even at the highest densities. Our results establish PCI as a reliable and versatile method for characterizing spatially dense atomic clouds.