Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:0705.0388 · Physical Review B

Sagnac rotational phase shifts in a mesoscopic electron interferometer with spin-orbit interactions

Marko Zivkovic, M. Jääskeläinen, Christopher P. Search, Ivana Djuric

Published Mar 6, 2008• 12 citations
arXivHTMLPDF

Abstract

The Sagnac effect is an important phase coherent effect in optical and atom interferometers where rotations of the interferometer with respect to an inertial reference frame result in a shift in the interference pattern proportional to the rotation rate. Here, we analyze the Sagnac effect in a mesoscopic semiconductor electron interferometer. We include in our analysis the Rashba spin-orbit interactions in the ring. Our results indicate that spin-orbit interactions increase the rotation-induced phase shift. We discuss the potential experimental observability of the Sagnac phase shift in such mesoscopic systems.

DOI
10.1103/physrevb.77.115306

Related papers

Sagnac effect in a chain of mesoscopic quantum rings

Christopher P. Search, John R. E. Toland, Marko Zivkovic

The ability to interferometrically detect inertial rotations via the Sagnac effect has been a strong stimulus for the development of atom interferometry because of the potential ${10}^{10}$ enhancement of the rotational phase shift in comparison to optical Sagnac gyroscopes. Here we analyze ballistic transport of matter waves in a one-dimensional chain of $N$ coherently coupled quantum rings in the presence of a rotation of angular frequency $\ensuremath{\Omega}$. We show that the transmission probability, $T$, exhibits zero transmission stop gaps as a function of the rotation rate interspersed with regions of rapidly oscillating finite transmission. With increasing $N$, the transition from zero transmission to the oscillatory regime becomes an increasingly sharp function of $\ensuremath{\Omega}$ with a slope $\ensuremath{\partial}T/\ensuremath{\partial}\ensuremath{\Omega}\ensuremath{\sim}{N}^{2}$. The steepness of this slope dramatically enhances the response to rotations in comparison to conventional single ring interferometers such as the Mach-Zehnder interferometer and leads to a phase sensitivity well below the quantum shot-noise limit typical of atom interferometers.

arXiv:0810.4111•Physical Review A•May 6, 2009•14 citations

Slow wave atom interferometers for rotation sensing

Meriç Özcan

A gyroscope based on Sagnac interferometer measures the rotation rate relative to an inertial frame of reference. Sagnac effect originally has been derived and experimentally demonstrated with optical waves. Later, matter wave based Sagnac interferometers were developed due to inherent sensitivity over a photon based system. However in any interferometer whether it is photon or matter wave based the resultant phase shift due to counter-rotating waves is independent of the wave velocity. Here we show that one can have a larger phase shift with slower matter waves using Aharonov-Bohm effect: the phase difference of the counter propagating waves is proportional to the inverse square of the particle velocity.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 8, 2007•0 citations

Sagnac experiment with electrons: Reanalysis of a rotationally induced phase shift for charged particles

Richard Neutze, FRANZ HASSELBACH

Using a path-integral formalism, we present a reanalysis of the Sagnac experiment with electrons of Hasselbach and Nicklaus [Phys. Rev. A 48, 143 (1993)]. Our analysis, from an inertial frame of reference, makes explicit the central role of the electrostatic biprism in generating interference fringes and recovers the Sagnac formula for the phase shift induced when rotating the interferometer. This phase shift, however, is shown to differ significantly in physical origin from the similar experiment with neutrons. In the electron Sagnac experiment, rotation displaces all classical electron paths closer to (or further from, depending upon direction) the electrostatic biprisms, thereby perturbing the electrostatic potential along these paths, and a phase shift of an electrostatic nature arises. Our analysis yields a corrected expression for the projected area of the interferometer and small numerical corrections to previous work are consequently given.

Physical Review A•Jul 1, 1998•16 citations

Sagnac experiment with electrons: Observation of the rotational phase shift of electron waves in vacuum

FRANZ HASSELBACH, Marc C. Nicklaus

A Sagnac experiment with electron waves in vacuum is reported. The phase shift caused by rotation of an electron biprism interferometer placed on a turntable has been measured. It was found to agree with prediction within error margins of about 30%. A compact ruggedized electron interferometer was used. It is based on a high-precision optical bench of 36-cm length. This interferometer is less sensitive by orders of magnitude to mechanical vibrations and electromagnetic stray fields than conventional electron interferometers. A beam of low-energy electrons (150--3000 eV) emitted by a field-emission electron source was used. For the most part, electrostatic electron optical components were employed. The magnified interference fringe pattern was intensified by a dual-stage multichannel-plate intensifier, recorded by a charge-coupled-device video camera, transmitted from the turntable to the laboratory system via a slip ring, and evaluated by an image-processing system. Both the rotation rate and the area enclosed between the two partial waves were varied (up to values of 0.5 ${\mathrm{s}}^{\mathrm{\ensuremath{-}}1}$ and 3.9 ${\mathrm{mm}}^{2}$, respectively). Fringe shifts on the order of 5% of a fringe period were attained. Some historical aspects of the Sagnac effect as well as some aspects of its interpretation are mentioned. A brief informal discussion is included of the interpretation of the Sagnac phase shift as a geometric phase (``Berry phase'') caused by the global anholonomy of the local phase factor that is produced by the gauge field induced by rotation.

Physical Review A•Jul 1, 1993•153 citations

Precision tests of the Sagnac effect with a two-axis atomic gyroscope

Leonid A. Sidorenkov, Romain Gauthier, Mohamed Guessoum +3 more

The Sagnac effect, manifest in the phase shift of a rotating interferometer proportional to its physical area and to the rotation rate of the frame, plays a crucial role in modern physics being generalized to any kind of interferometer. However, as compared to light, the accurate experimental validation of the Sagnac effect for matter-waves remains challenging. We report the accurate measurement of the Sagnac phase shift, induced by the Earth’s rotation, using a large-area cold atom interferometer. We probe the atomic Sagnac phase shift along the two orthogonal horizontal axes in various orientation of the sensor with respect to geographic north and obtain an agreement with the theoretical prediction at the 20 ppm level, improving by twenty five-fold over the previous achievements for matter waves. Our results underline the universality of the Sagnac effect and open new horizons for testing other fundamental theories, as well as for a number of technological applications in seismology, geodesy and inertial navigation systems.

Quantum Sensing and Nano Electronics and Photonics•Mar 8, 2024•0 citations

Accurate measurement of the Sagnac effect for matter waves

Romain Gautier, Mohamed Guessoum, Leonid A. Sidorenkov +3 more

A rotating interferometer with paths that enclose a physical area exhibits a phase shift proportional to this area and to the rotation rate of the frame. Understanding the origin of this so-called Sagnac effect has played a key role in the establishment of the theory of relativity and has pushed for the development of precision optical interferometers. The fundamental importance of the Sagnac effect motivated the realization of experiments to test its validity for waves beyond optical, but precision measurements remained a challenge. Here, we report the accurate test of the Sagnac effect for matter waves, by using a Cesium atom interferometer featuring a geometrical area of 11 cm 2 and two sensitive axes of measurements. We measure the phase shift induced by Earth’s rotation and find agreement with the theoretical prediction at an accuracy level of 25 parts per million. Beyond the importance for fundamental physics, our work opens practical applications in seismology and geodesy.

arXiv:2206.06696•Science Advances•Jun 10, 2022•53 citations
The Sagnac effect is an important phase coherent effect in optical and atom interferometers where rotations of the interferometer with respect to an inertial reference frame result in a shift in the interference pattern proportional to the rotation rate. Here, we analyze the Sagnac effect in a mesoscopic semiconductor electron interferometer. We include in our analysis the Rashba spin-orbit interactions in the ring. Our results indicate that spin-orbit interactions increase the rotation-induced phase shift. We discuss the potential experimental observability of the Sagnac phase shift in such mesoscopic systems.
The ability to interferometrically detect inertial rotations via the Sagnac effect has been a strong stimulus for the development of atom interferometry because of the potential 1010{10}^{10}1010 enhancement of the rotational phase shift in comparison to optical Sagnac gyroscopes. Here we analyze ballistic transport of matter waves in a one-dimensional chain of NNN coherently coupled quantum rings in the presence of a rotation of angular frequency $\ensuremath{\Omega}$. We show that the transmission probability, TTT, exhibits zero transmission stop gaps as a function of the rotation rate interspersed with regions of rapidly oscillating finite transmission. With increasing NNN, the transition from zero transmission to the oscillatory regime becomes an increasingly sharp function of $\ensuremath{\Omega}$ with a slope $\ensuremath{\partial}T/\ensuremath{\partial}\ensuremath{\Omega}\ensuremath{\sim}{N}^{2}$. The steepness of this slope dramatically enhances the response to rotations in comparison to conventional single ring interferometers such as the Mach-Zehnder interferometer and leads to a phase sensitivity well below the quantum shot-noise limit typical of atom interferometers.
A gyroscope based on Sagnac interferometer measures the rotation rate relative to an inertial frame of reference. Sagnac effect originally has been derived and experimentally demonstrated with optical waves. Later, matter wave based Sagnac interferometers were developed due to inherent sensitivity over a photon based system. However in any interferometer whether it is photon or matter wave based the resultant phase shift due to counter-rotating waves is independent of the wave velocity. Here we show that one can have a larger phase shift with slower matter waves using Aharonov-Bohm effect: the phase difference of the counter propagating waves is proportional to the inverse square of the particle velocity.
Using a path-integral formalism, we present a reanalysis of the Sagnac experiment with electrons of Hasselbach and Nicklaus [Phys. Rev. A 48, 143 (1993)]. Our analysis, from an inertial frame of reference, makes explicit the central role of the electrostatic biprism in generating interference fringes and recovers the Sagnac formula for the phase shift induced when rotating the interferometer. This phase shift, however, is shown to differ significantly in physical origin from the similar experiment with neutrons. In the electron Sagnac experiment, rotation displaces all classical electron paths closer to (or further from, depending upon direction) the electrostatic biprisms, thereby perturbing the electrostatic potential along these paths, and a phase shift of an electrostatic nature arises. Our analysis yields a corrected expression for the projected area of the interferometer and small numerical corrections to previous work are consequently given.
A Sagnac experiment with electron waves in vacuum is reported. The phase shift caused by rotation of an electron biprism interferometer placed on a turntable has been measured. It was found to agree with prediction within error margins of about 30%. A compact ruggedized electron interferometer was used. It is based on a high-precision optical bench of 36-cm length. This interferometer is less sensitive by orders of magnitude to mechanical vibrations and electromagnetic stray fields than conventional electron interferometers. A beam of low-energy electrons (150--3000 eV) emitted by a field-emission electron source was used. For the most part, electrostatic electron optical components were employed. The magnified interference fringe pattern was intensified by a dual-stage multichannel-plate intensifier, recorded by a charge-coupled-device video camera, transmitted from the turntable to the laboratory system via a slip ring, and evaluated by an image-processing system. Both the rotation rate and the area enclosed between the two partial waves were varied (up to values of 0.5 ${\mathrm{s}}^{\mathrm{\ensuremath{-}}1}$ and 3.9 mm2{\mathrm{mm}}^{2}mm2, respectively). Fringe shifts on the order of 5% of a fringe period were attained. Some historical aspects of the Sagnac effect as well as some aspects of its interpretation are mentioned. A brief informal discussion is included of the interpretation of the Sagnac phase shift as a geometric phase (``Berry phase'') caused by the global anholonomy of the local phase factor that is produced by the gauge field induced by rotation.
The Sagnac effect, manifest in the phase shift of a rotating interferometer proportional to its physical area and to the rotation rate of the frame, plays a crucial role in modern physics being generalized to any kind of interferometer. However, as compared to light, the accurate experimental validation of the Sagnac effect for matter-waves remains challenging. We report the accurate measurement of the Sagnac phase shift, induced by the Earth’s rotation, using a large-area cold atom interferometer. We probe the atomic Sagnac phase shift along the two orthogonal horizontal axes in various orientation of the sensor with respect to geographic north and obtain an agreement with the theoretical prediction at the 20 ppm level, improving by twenty five-fold over the previous achievements for matter waves. Our results underline the universality of the Sagnac effect and open new horizons for testing other fundamental theories, as well as for a number of technological applications in seismology, geodesy and inertial navigation systems.
A rotating interferometer with paths that enclose a physical area exhibits a phase shift proportional to this area and to the rotation rate of the frame. Understanding the origin of this so-called Sagnac effect has played a key role in the establishment of the theory of relativity and has pushed for the development of precision optical interferometers. The fundamental importance of the Sagnac effect motivated the realization of experiments to test its validity for waves beyond optical, but precision measurements remained a challenge. Here, we report the accurate test of the Sagnac effect for matter waves, by using a Cesium atom interferometer featuring a geometrical area of 11 cm 2 and two sensitive axes of measurements. We measure the phase shift induced by Earth’s rotation and find agreement with the theoretical prediction at an accuracy level of 25 parts per million. Beyond the importance for fundamental physics, our work opens practical applications in seismology and geodesy.